Before attempting to move the unit, empty the contents of the water tank. Use carrying handle (fig1.10)when moving unit.
9
Switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.
9
Ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children.
9
NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
2. INTRODUCTION
Thermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features
two-speed fan and electronic remote control. Air conditioning temperature range 16-30°C. Also features a dehumidifying
function capable of removing up to 24L/day. Refrigerant is R290. Mounted on castors for manoeuvrability. Cable storage keeps unit
tidy when not in use.

3. SPECIFICATION

Model No.:..............................................................SAC9002
Cooling capacity: ...................................................9000Btu/hr
Discharge side pressure: ...........................................3.8MPa
Energy rating: ...................................................... A (Cooling)
IP rating: .........................................................................IP20
Mass of refrigerant: ........................................................ 270g
Max. airflow: .............................................................360m³/hr
Max. exhaust hose length: ............................................. 1.5m
Max water extraction rate: ......................................... 24L/day
Noise level: .............................................................. 65db (A)
Power: .........................................................................1010W
Rated capacity: ...........................................................2640W
Refrigerant: ................................................................... R290
Suction side pressure: ............................................... 1.3Mpa
Supply: ................................................................ 230V~50Hz
4. CONTENTS (SEE FIG.1)
1
Control panel
2
Horizontal louvre
3
Vertical louvre
4
Air outlet frame
5
Vertical Louvre connecting lever
6
Caster
7
Horizontal louvre connecting lever
8
Main vertical louvre
9
Front shell
10
Handle position (right side: remote control storage area)
11
Back shell
12
Retaining clip (exhaust hose)
13
Power cord

5. INSTALLATION

WARNING! leave this mobile air-conditioner in an upright position for at least 2 hours before first use. Ensure that the air
conditioner remains in an upright position whilst it is being moved. Place the air-conditioner on a flat ground surface.
5.1.
Connector fig.1.24 and Window sealing board assembly fig.1.26 are fitted to Exhaust Hose fig.1.25. Place 25 and 26 at each end of
the hose and screw clockwise onto the hose to connect.
fig.2
5.2.
Select the exhaust hose retaining clamp.
5.3.
Fit the exhaust hose to the circular aperture at the rear and secure with the retaining clip.
5.4.
Rotate the retaining clip anticlockwise and snap the retaining clamp closed to secure the heat exhaust hose.
© Jack Sealey Limited
fig.1
14
15
16
17
18
19
20
21
22
23
24
25
26
Original Language Version
Lower air duct bottom
Wire-winding post
Drain cap
Evaporator filter mesh
Evaporator filter frame
Radiating fine mesh
Condenser filter mesh
Condenser filter frame
Base plate
Remote control
Heat exhaust hose short connector
Exhaust hose
Window sealing board assembly
fig.3
SAC9002
fig.4
Issue 1
19/03/20