Axis ATA1200 User Manual page 53

Table of Contents

Advertisement

53
USER MANUAL
__________________________________________________________________________________________________________________
Relays connection diagram:
Imax < 25mA
Relays output is the open collector transoptor output with load capacity 25mA / 24V. Transmitter inputs
must be protected with diodes, e.g. 1N4148.
It is advised to use MS3K/P electronic board (sold separately), consisting of RM96P transmitters, with
DC24V input voltage and AC250V, 3A output.
Important notes:
1. After switching the scale on, both thresholds are set to maximum values.
2. When setting upper threshold value, pay attention that its value is not below lower threshold value.
3. Setting lower and upper threshold value is possible after sending appropriate orders from computer,
what is described in scale user manual.