Advertisement

USER MANUAL
BD/TL Series
File: 2014-12-08 BD_TL-162 BTL004 GB

Advertisement

Table of Contents
loading

Summary of Contents for Axis BD/TL Series

  • Page 1 USER MANUAL BD/TL Series File: 2014-12-08 BD_TL-162 BTL004 GB...
  • Page 2: Table Of Contents

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Index: 1. General description ..................... 3 2. Completeness ......................3 3. Security rules ....................... 4 4. Technical data ......................5 5. General view of balance ....................6 6. Keys and indicators ..................... 8 7. Preparation of workplace ................... 11 8.
  • Page 3: General Description

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 1. General description BD/TL series scales are destined for identical pieces counting and can be used in store houses production control and similar tasks. Counting pieces function is based on calculation individual mass of detail from inscribed value using keyboard.
  • Page 4: Security Rules

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 3. Security rules To avoid electrical shock or damage of the scale or connected peripheral devices, it is necessary to follow the security rules below.  All repairs and necessary regulations can be made by authorised personnel only.
  • Page 5: Technical Data

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 4. Technical data Scale type BD1.5TL BD3TL BD6TL BD15TL BD30TL Load (Max) 1.5kg 15kg 30kg 0,5g Readout unit (d) *0,05g *0,1g *0,2g *0,5g Tare range -1.5kg -3kg -6kg -15kg -30kg Pan dimensions 300x210mm Working temperature -10°C ÷ +40°C Weighing time <3s Scale dimensions...
  • Page 6: General View Of Balance

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 5. General view of balance Front view: 1 – Overlay pan 4 – keyboard 2 – suport pan (under overlay p.) 5 – level 3 – display 6 – rotary legs Back view: Back view - option with additional displays:...
  • Page 7 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Interfaces view: RS232C Feeder RxD (receiver) Supply TxD (transmitter) (option) Attention: +5V (option) supply in RS232C joint is installed only in scales ordered together with a scanner. In that case the scanner doesn’t need feeder.
  • Page 8: Keys And Indicators

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 6. Keys and indicators Keys placement: Keys description: - turn on/off, - print key (complies with port and print settings), - scale zeroing key (verificated scale), - scale tare key, - short press – enter user menu, - hold –...
  • Page 9 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ - short press – substraction of actual netto weight / details quantity from TOTAL register, - hold –TOTAL menu acces (release key to choose actually displayed option) - short press – pieces counting on (putting defined quantity of pieces on pan), - hold –...
  • Page 10 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Scale indications: ◄ ◄ ◄ Scale display is divided into three sections: WEIGHT - upper, DATA - middle and COUNT - lower. Each of these sections has its own measurement indication and information indicators that complement main information or describe scale state.
  • Page 11: Preparation Of Workplace

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ indicator ▲ - signalizes that APA option (automatic improving of pieces counting accuracy)is on / in scale’s menu indicates if function is on (indicator indicates) or off (without indicator). 7. Preparation of workplace Workplace of scale should be chosen carefully. This place should be assured a proper temperature and essential area for attendance.
  • Page 12: General Rules

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ If scale has been moved from places with low temperature to places with high temperature (for example in winter), before connecting the scale to supply leave it for about 4 hours in purpose of acclimatization. 9. General rules 1.
  • Page 13: Operation Rules During Work With Accumulators (Batteries)

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 10. Operation rules during work with accumulators (batteries) 1.Scale can be powered from ~230V supply through feeder attached with scale. Moreover accumulators, which are placed in container inside the scale, can be used for powering. Ordinary batteries can be used as well. When using batteries in place of accumulators, charging during work with feeder have to be switched off.
  • Page 14: Accumulator Exchange

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 11. Accumulator exchange 1.Remove the pan carefully. 2.Invert the scale. red color 3.Remove the cover 12. 4.Unscrew tab bolts 16, remove accumulator clamp 15, remove sleeves 13 , remove used accumulator 14. 5.Sleeves 13 put on new accumulator 14 , check the polarization (on accumulator + indicated by red color put sleeve with red color).
  • Page 15: Start Of Work

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 12. Start of work Leave the pan empty, plug the feeder to the mains (~230V/50Hz) and plug the feeder connector to the 12V power socket at the bottom side of the scale. Scale will execute following step: - display type of scale and version of program, - zeroing the indication.
  • Page 16 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Measurement with single pieces removing from pan: A measurement is performed in two phases: - first phase - single piece weight calculation on the basic of removed pieces (default is 10 pieces), - second phase – recalculating pieces in weighting portion. ◄...
  • Page 17 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Change/write a unitary mass using numeric keys: During pieces counting (indicator PCS) user can change actual sample mass. Writing a sample mass when counting process is turned-off initiates counting process.  1. Press SPW key. 2. Write sample mass using numeric keys and press ENTER. 3.
  • Page 18: Summation Of Measurements Series ( .)

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 14. Summation of measurements series ( .) Scale is equipped with summation register. The register enables adding successive results of measurements. ◄ Total ◄ 114.8 ◄  1. Put weighted element on the pan and press + button.
  • Page 19: Permanent Tare Memory (→Pt)

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 15. Permanent tare memory (→PT) The scale can store up to 10 tare values in memory that can be later recalled. The option enables gross weight measurement (pieces quantity) of product in for eg. container of known weight, and then readout of calculated net weight (pieces quantity).
  • Page 20: Products Data Library ( Mem Key )

    Scale Database software and scale’s serial interface. Scale Database is available on our webpage www.axis.pl/en. Handy products banks The scale is equipped with two handy detail banks: M1 and M2, that are related to fast choice keys M01÷M15 and M16÷M30.
  • Page 21 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Products data edition (records) Products data can be edited by holding chosen fast choice key or by using  MEM key and inscribing record number.  Longer pressing of key causes record number inscribing screen displaying. M no On upper section display M no sign shows up and on the middle section a field to inscribe record number ( from 1 to 1000).
  • Page 22 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________   - or →0← button. To speed up options displaying user can press To choose option press ENTER key. After choosing the proper option user can insert numerical value using keyboard and confirm it with ENTER key. Recalling record ...
  • Page 23: Connecting To Computer Or Printer

    When cooperating with the scale, a computer should be equipped with a program which enables processing data from the scale The Axis company offers programs to cooperating with scales. These programs are available on site www.axis.pl - Test RS232C- program to tests serial connections (full version), - ProCell –...
  • Page 24 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Connecting cable WK-1 (connect scale with computer / interface 9-pin): SCALE COMPUTER Connecting cable WD-1 (connect scale with printer KAFKA): SCALE KAFKA PRINTER Settings og internal switch printer AXIS: SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8...
  • Page 25: Basic Function Description

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 18. Basic function description 18.1 Zeroing scale indication If the scale pan is unloaded and weight indication is other than zero, press T key. ◄ ◄ ◄ ◄ ◄ ◄...
  • Page 26: Tare

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 18.2 Tare Scale enables to tare (zeroing the scale when there is a package on the pan) in whole measurement range. Total tare and net weight value cannot exceed scale’s range (Max). package ◄ ◄ ◄ measured object ◄...
  • Page 27: User Menu

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ 19. User menu Pressing MENU key enables to use many options, special functions and scale configuration. Option names show up successively in upper section display. To choose displayed option press ENTER key. - PCS SAMPL view and edition of default sample quantity; inscribing new value using numerical keys and confirmation by ENTER key, turning on (On) or off (OFF) automatic pieces counting correction function,...
  • Page 28 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ - totAL ModE totAL register measurement confirmation mode: manual (MAnUA) –after pressing ∑ key, automatic (Auto) – after indication stabilization, PrInt totAL work with (On) printout or without (OFF), SAVE totAL summing register saved to non-volatile memory (On) or reset after each turning off the scale (OFF).
  • Page 29 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ - dAtA_b EdIt inscribing number/code (MODE key switches) of the part to edit, dELOnE inscribing number/code (MODE key switches) parts to delete, confirmation YES/no, dELALL deleting all parts, confirmation YES/no. Products edition enables to define: - PA Id – detail number inscribing, - APW –...
  • Page 30 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ SErIAL Port-1 and Port-2 serial parameters : - transmission speed (bAud): 1200, 2400 4800, 9600, 19200, 38400, 57600bps, - quantity of bits in byte (bitS): 7, 8, - parity control (ParItY): none – no control, Odd – non-parity, Even - parity, - continous transmission (Send): oFF –...
  • Page 31: Maintenance And Repairs Of Small Defects

    4. It is forbidden to make any repairs by unauthorised persons. 5. To repair the scale, please contact our nearest service. List of authorized services is shown on site: www.axis.pl. 6. Damaged scales should be sent to repair in original package only. Scale should be protected against pressure.
  • Page 32 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ the scale was switched on with remove the load from the pan loaded pan unstable ground place the balance on a stable vibrations ground not affected by mechanical vibrations and air flows indicator does airflows not appear balance damage contact an authorized service - - - - - -...
  • Page 33: Declaration Of Conformity

    OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Declaration of Conformity AXIS Spółka z o.o. 80-125 Gdańsk, ul.Kartuska 375B confirm with all responsibility that scales: BD1.5TL, BD3TL, BD6TL, BD15TL, BD30TL and BD3TLY, BD6TLY, BD12TLY, BD30TLY marked with CE mark comply the following: 1. Directive 2004/108/WE (Electromagnetic compatibility) and norms harmonized with: ...
  • Page 34 OPERATION MANUAL BD/TL __________________________________________________________________________________________________________________ Notes...

This manual is also suitable for:

Bd15tlBd6tlBd3tlBd30tl

Table of Contents