Model VRT4032ZMN
• Rating (Variable): 17,000/25,000 Btu/Hr
• Type Gas: Natural Gas Only
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
Model VRT4036ZMN
• Rating (Variable): 20,000/33,000 Btu/Hr
• Type Gas: Natural Gas Only
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
See Pages 33-37 for a complete replacement parts
list. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your
IHP distributor or dealer. Parts will be shipped at
prevailing prices at time of order.
NEVER USE SUBSTITUTE MATERIALS. USE OF
NON-APPROVED PARTS CAN RESULT IN POOR
PERFORMANCE AND SAFETY HAZARDS.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• appliance will not produce specifi ed heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
30

WIRING DIAGRAM

disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation. Verify proper
operation after servicing.
Thermopile
SPECIFICATIONS
Model VRT4032ZMP
• Rating (Variable): 17,000/25,000 Btu/Hr
• Type Gas: Propant/LP Only
• Ignition: Piezo
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water)
• Shipping Weight: 122 lbs.
* For input adjustment
Model VRT4036ZMP
• Rating (Variable): 20,000/33,000 Btu/Hr
• Type Gas: Propant/LP Only
• Ignition: Piezo
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water)
• Shipping Weight: 122 lbs.
* For input adjustment

REPLACEMENT PARTS

When ordering repair parts, always give the follow-
ing information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any ques-
tions concerning the installation or application of
this appliance, please contact your dealer.
You may have further questions about instal-
lation, operation, or troubleshooting. Please
contact your IHP dealer for any questions or
concerns. When contacting your dealer please
have your model and serial numbers of your
appliance ready. You can also visit our web site
at SuperiorFireplaces.us.com.
SuperiorFireplaces.us.com
CAUTION: Label all wires prior to
Maximum 13" W.C., Minimum* 11" W.C.
Maximum 13" W.C., Minimum* 11" W.C.

TECHNICAL SERVICE

126868-01B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents