OBSERVED PROBLEM
When igniter button is pressed,
there is no spark at ODS/pilot
When igniter button is pressed,
there is spark at ODS/pilot but
no ignition
26

TROUBLESHOOTING

POSSIBLE CAUSE
1. Igniter electrode not con-
nected to igniter cable
2. Igniter cable pinched or wet
3. Piezo igniter nut is loose
4. Broken igniter cable
5. Bad piezo igniter
6. Igniter electrode broken
7. Igniter electrode positioned
wrong
1. Gas supply turned off or
equipment shutoff valve
closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when in-
stalled
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
SuperiorFireplaces.us.com
REMEDY
1. Reconnect igniter cable
2. Free igniter cable if pinched
by any metal or tubing. Keep
igniter cable dry
3. Tighten nut holding piezo
igniter to base panel of log
set. Nut is located behind
base panel
4. Replace igniter cable
5. Replace piezo igniter
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while
in PILOT position
4. Continue holding down
control knob. Repeat ignit-
ing operation until air is
removed
5. Contact local propane/LP
gas company
6. C l e a n O D S / p i l o t ( s e e
Cleaning and Maintenance,
Page 25) or replace ODS/
pilot assembly
7. Replace gas regulator
126868-01B