7. With control knob pressed in, press and
release igniter button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing igniter button until
pilot lights.
NOTE: If pilot does not stay lit, contact a
qualifi ed service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
NOTE: If pilot goes out, repeat steps 4
through 8 beginning on Pages 22-23.
9. Slightly push in and turn control knob coun-
terclockwise
10. Wait one minute to light burners.
11. Set fl ame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF po si tion.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Igniter
Button
AUTO
OFF
Control Knob
ON
Figure 39 - Control Knob and Igniter
Button Location
Pilot Burner
Figure 40 - Pilot
126868-01B
OPERATION
Continued
to the ON position.
to the
Flame Adjustment
Knob
Igniter
Electrode
SuperiorFireplaces.us.com
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
the OFF position.
2. Close equipment shutoff valve (see Fig-
ure 21, Page 17).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, Page 22.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11, column 1.
BLOWER
OPERATION
WARNING: This fi replace has
a three-prong, grounded electri-
cal plug. This plug helps protect
you against electrical shock.
Only connect plug to a properly
grounded, three-prong recep-
tacle. Do not cut or remove the
grounding prong from this plug.
Access the blower control knob by pushing in
on the bottom corners of the fi replace screen,
grasp the bottom of the screen and pull out
and up to remove the screen. The blower
control knob is located on the left side of the
fi replace fl oor.
The blower is thermostatically controlled. This
means the fi replace and blower will not turn
on and off at the same time. The fi replace
may run for several minutes before the blower
turns on. After the fi replace is shut off, the
blower will continue to operate until the fi re-
place temperature cools.
The blower also includes a variable speed
control. Turn the knob clockwise to turn the
blower to the high position. Continuing to turn
the knob will reduce the speed of the blower
until it reaches a preset low speed.