Service Mode Entry
The control must be in the idle state to enter Service Mode.
Press and release My Cycle, then press and release Delay Dry, then press and release My Cycle, then press
and release Delay Dry. T1 will be displayed if keys were properly pressed.
•
Rotate the cycle select knob CW to increase the test number.
•
Rotate the cycle select knob CCW to decrease the test number.
•
Press the Start key to enter a test.
•
Turn the cycle select knob to exit the test.
Service Mode Exit
Press the Power key or disconnect power from unit. Service Mode will automatically time out after 5 minutes
if there is no user activity.
Service Mode Tests
Diagnostics
Service Mode
My Cycle
Test #
SSD
1
t1
2
t2
3
t3
4
t4
5
t5
6
t6
7
t7
8
t8
9
t9
10
t10
11
t11
12
t12
13
t13
Delay Dry
Test Function
Model Codes
UI Software Version
XML Version
Error Codes
CRC Non-Volatile Memory
User Interface
Outlet Thermistor
Inlet Thermistor
Moisture Sensor
Door Open/Closed
Water Valve
Restore EEPROM
Drum
14