Disassembling The Shutter Linkage - Polaroid ID-200 Repair Manual

Table of Contents

Advertisement

Repair Manual

Disassembling the Shutter Linkage

Disassembly
1.
Remove the Shutter Assembly. (See "Removing the Shutter Assembly,"
page 54)
2.
Disengage the Release Lever Spring. (Refer to Figure 4-17 for all steps
below)
3.
Remove the e-ring and lift the Release Lever from its post.
4.
Remove the e-ring and small phillips tapping panhead screw, washer and
Wheel Spring from the Pressure Lever; lift the Pressure Lever from its
post.
5.
Remove the Release Lever Spring.
6.
Remove the e-ring from the post on the Wheel; lift the Wheel Spring from
the Wheel.
7.
Disengage the Button Spring from the Right Button and Left Button.
8.
Remove the e-ring from the Right Button and Left Button; lift both Buttons
from their posts.
9.
Remove the e-ring from the Wheel and lift the Wheel from its post.