Download Print this page

Wiring Details For Internal Eol Resistors; Wiring Examples - Honeywell IS3050A Installation Instructions Manual

Passive infrared motion sensor with anti-mask

Advertisement

WIRING DETAILS FOR INTERNAL EOL RESISTORS

- Observe proper polarity.
- Connect the sensor to the panel (see
wiring diagrams below).
- For Vista panels, set the Internal 2K EOL
switch ON (factory default).

Wiring Examples

To connect all three outputs (sensor alarm,
tamper and trouble/anti-mask) to one zone
input: All alarm, tamper and trouble/anti-mask
events are "alarms" when the system is armed or
"fault" when disarmed.
To connect the sensor alarm output to one
zone input and the tamper and trouble/anti-
mask outputs to a second zone input: The
alarm relay is wired to one zone; the tamper and
trouble/anti-mask are wired to another zone; the
control panel differentiates alarm conditions from
tamper and trouble/anti-mask conditions.
To connect the sensor alarm, tamper and
trouble/anti-mask outputs to three separate
zone inputs: The alarm, tamper and trouble/anti-
mask are each wired to a separate zone; the
control panel differentiates alarm, tamper and
trouble/anti-mask conditions.
Notes:
- Consult the Control Panel manual to determine proper EOL selection.
- The EOL setting must only have one switch ON.
- If not using the internal EOL resistors, set all switches to OFF.
- 3 -