Download Print this page

Detection Patterns; Flashlight Feature - Honeywell IS3050A Installation Instructions Manual

Passive infrared motion sensor with anti-mask

Advertisement

1. Close the sensor and apply power to the sensor. Initialization is complete when the LED stops flashing slowly
(about 20 seconds).
2. Walk through the detection area and observe the LED.
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation mode. For an additional 10 minute walk test, enable Walk Test mode again with the flashlight feature:
Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting.

Flashlight Feature:

1. Use a flashlight with a bright light beam, and stand within 4' (1.2 m) of the sensor.
2. Swing the light beam past the sensor IR window 3-5 times, holding the beam
on the window for 0.5 second each pass.
The flashlight feature is only available for the first 24 hours after the first power up.
LED
Red
Yellow
- 4 -
Power
Walk Test
Normal
Trouble Anti-Mask
Up
Slow
ON
ON
Blink
Alarm
Alarm
OFF
OFF
OFF
Zones
2
A
Look-down
12
B
Lower
10
C
Intermediate
36
D
Long
Fast
OFF
Blink
Fast
OFF
Blink

Advertisement