ADJUSTMENT INSTRUCTIONS

REMOVING AND INSTALLING THE BLADE
WARNING
!
source outlet.
NOTE: The miter saw comes with the
saw blade already installed.
1. Unplug the saw from the outlet.
2. Raise the cutting head to the upright
position.
3. Raise the lower blade guard (1) to the
uppermost position. (Fig. N)
4. Loosen the cover plate screw (2) with a
Phillips screwdriver.
5. Rotate the cover plate (3) back to expose
the arbor bolt (4).
6. Place the provided blade wrench over the
arbor bolt (4).
7. Locate the arbor lock button (5) below the
trigger switch handle. (Fig. O)
8. Press the arbor lock button (5), holding
clockwise. This will engage the arbor lock
allowing the arbor bolt to be loosened
with the blade wrench. Continue to hold
the arbor lock button (5) while turning the
wrench clockwise to loosen the arbor bolt.
9. Remove the arbor bolt (4), the outer blade
collar (6), and the blade (7). (Fig. P)
CAUTION
!
Do not remove the inner blade collar (8).
NOTE: Pay attention to the pieces removed,
noting their position and direction they face.
Wipe the blade collars clean of any sawdust
before installing a new blade.
6
4
1
WARNING
!
1. Install a 10 in. blade with a 5/8 in. arbor
2
hole, making sure the rotation arrow on
the blade matches the clockwise rotation
3
arrow on the upper guard, and the blade
teeth are pointing downward at the front
of the saw.
4
2. Place the blade (7) onto the arbor (9) and
against the inner blade collar (8). Then,
place the outer blade collar (6) and thread
the arbor bolt (4) conterclockwise onto the
arbor. (Fig. P)
IMPORTANT:
collars must be placed against the blade.
Do not install the collars with the curved
side against the blade.
3. Place the blade wrench on the arbor
bolt (4).
19
5
7
Do not
remove
8
9