Voltage Input:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC 60 Hz
Power Consumption:
Operating Temperature:
Operating Humidity:
Dimensions:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11"W x 9" H x 3 ¾" D
Weight:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MInI-Mod-cnc specIfIcatIons
Switch Between Boiler Groups:
Lead Stage Rotation:
Pump Output:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 N.O. S.P.S.T
Modulating Boiler Modes:
Staging Boiler Modes:
Standby Time:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 to 60 minutes
Modulating Output Types:
Sequencing Output Types:
Output Relay Ratings:
Add-On Mini-Extension Panels:
Ignition Point %:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 50%
Modulation Start Point %:
Modulation Modes:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal or Parallel
Sequencing Modes:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lo/Hi/Lo/Hi or Lo/lo/Hi/Hi
Temperature Display:
Display:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Graphical Alphanumeric (up to 7 rows x 21 char. each)
LED:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 System Output relay, 4 Boiler Output relays
Sensor Ranges:
. . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor temperature sensor - minus 35
Outdoor Cutoff Range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset Ratio Range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (
Offset Adjustment:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . minus -50F°/-28C
Minimum Water Temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Water Temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Domestic Hot Water:
Pump Run-On:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 360 minutes
Purge Delay:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.0 to 10.0 minutes
Lag Delay:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 60 minutes
Last Stage Hold:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 30°F
Schedules:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Day and 1 Night (Setback) setting per day
Night Setback:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0F°/0C
Power Backup:
. . . . . . . . . Lithium coin battery, 100 days minimum 5 year replacement (Maintains Clock in power outages)
External Inputs:
. . . . . . . . . . . . Shutdown, Tstat, and Setback Input, and Prove and DHW Call Input. (Dry Contacts Only)
Season:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Winter and Summer
MInI-extensIon specIfIcatIons
(Each Mini-Extension can add up to (6) additional modulating boilers. A maximum of two Mini-Extensions can be added to a
single Mini-MOD-CNC.)
Extension Numbering:
Boiler Outputs:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (6) N.O. S.P.S.T.
Modulating Output Types:
Output Relay Ratings:
Connection to Mini-MOD-CNC and another extension:

specIfIcatIons

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VA Max
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20% to 80% non-condensing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Target Temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time ( 1 to 1440 Hours (60 days)), Manual, Last-On
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto, Manual, Standby, On, Off
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto, Standby, On, Off
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On/Off, 2-Stage, 3-Stage, or 4-Stage
. . . . . . . . . . . . . . .1 Amp inductive, 6Amp resistive at 120 VAC 60 Hz, 15A total for all circuits
. . . . . . . . . . . . . . . . . . . . . . . . . up two Mini-Extension Panels using RS485
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 100%
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fahrenheit or Celsius
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . with Priority or without Priority
. . . . . . . . . . . .Toggle Switch A (Stages E - J, LEDs are Green) or B (Stages K - P, LEDs are Red)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (6) 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V
. . . . . . . . . . 1 Amp inductive (1/8HP), 6Amp resistive at 120 VAC 60 Hz, 15A total for all circuits
20 new dutch lane, fairfield, nJ 07004 973-575-4004 • fax 973-575-4052 • http://www.Heat-timer.com
Heating system sensor - minus 35
1:4) to (4:1) (Outdoor : System Water)
. . Two RS485 connections using phone style cable (Cable is
F/-6
C to 130
F/54
°
°
°
2.5 pounds
F/-37
C to 250
F/121
°
°
°
F/-37
C to 250
F/121
°
°
°
20°F/-6
C to 100°F, ON and OFF
°
to plus 50F°/28C
°
70
F/21
C to 170
F/77
°
°
°
90
F/32
C to 240
F/116
°
°
°
to 75F°/42C
°