PROGRAMMING
Owner Options Continued:

Select Units:

(Used to program the operator's personal preferences for the liquid and weights measurement the DIG-220 will display.)
1.
Press
or
until "Select Units" is displayed; then press SELECT ( " English Units" is the factory setting).
2.
Press
or
until desired measurement "English Units" (gallons and pounds), or " M etric Units" (liters and kilograms), is displayed; then press SELECT .

Temperature Units:

(Used to set the personal preference (C or F) for temperature display .)
1.
Press
or
until "Temperature Unit" is displayed; then press SELECT ("Fahrenheit" is the factory setting).
2.
Press
or
until desired measurement unit "Fahrenheit" or "Celsius" is displayed; then press SELECT .

12/24 Hour Clock:

(Allows for personal preference time clock display)
1.
Press
or
until "12/24 hour clock" is displayed; then press SELECT (12 hour clock is the factory setting).
2.
Press
or
until the desired clock format (12-hour or 24-hour clock) is displayed, then press SELECT .

Set Time of Day:

(Allows for changes to the time of day displays for time zones or day-light savings.)
1.
Press
or
until desired hours are displayed; then press SELECT .
2.
Press
or
until the desired minutes are displayed; then press SELECT .
Exit Menu Mode:
Press SELECT to exit menu entry.

Maintenance Menu:

Press MENU, press
or
Press
or
for desired selections, followed by SELECT
Once all modifications are complete, press

Test Pool Pilot:

(Diagnostic Menu)
The display will automatically toggle through the following displays ( or
the remaining displays and exit back to normal operation):
"Salt =XXXX ppm (X.x g/l)" (The optimum salt level is 3000 ppm (3.0 g/l) 4500 ppm for maximum chlorine production)
"Add Salt xx Lbs (xx Kg)" (The amount of salt needed to maintain 3000 ppm (3.0 g/l))
"Temperature XX° F (XX° C)" (The temperature of the water flowing through the Tri-sensor)
"Cell = XX V XX.x A" (The measured voltage and current sent to the Pool Pilot Cell)
"Amp-Hrs = xxxxxx" (The amount of current times hours of operation received by the Pool Pilot Cell) . This is only viewable if "Test Pool Pilot" was selected under the
"Maintenance Menu."
Set Time of Day:
(Allows for changes to the time of day displays for time zones or day-light savings.)
1.
Press
or
until desired hours are displayed; then press SELECT .
2.
Press
or
until the desired minutes are displayed; then press SELECT .

Force Reverse:

Note: this is a diagnostic tool, only, and should not be used unless a problem is suspected.
(This function activates a reverse cycle, which can be used to verify that the self-cleaning feature is working). After selecting "Force Reverse" there will be a 40
second delay before proceeding. During the delay "Cell reversing" will display.
1.
Press
or
until "Force Reverse" is displayed; then press SELECT .
3.
"Cell reversing" will display temporarily for 40-seconds.
The "."(period) on the end of 2

Set Reverse Time:

(Used to program the Pool Pilot Cell's self-cleaning cycle.)
NOTICE
1.
Press
or
until "Set Reverse Time" is displayed; then press SELECT (4-hours is the factory setting).
2.
Press
or
until the desired cycle time (2, 4, 8, or 16 hours) is displayed; then press SELECT .
until "Maintenance Menu" is displayed; then press SELECT .
or
until "Exit Menu Mode" is displayed; then press SELECT. The menu will also time out after 20 seconds of no key activity.
line of the display will either appear, or disappear—based on its previous state—to indicate cell power polarity has reversed.
nd
Failure to heed the following may result in equipment damage.
Reduced polarity reversing cycle times will reduce Pool Pilot Cell life, and
should only be used due to uncontrollable scale formation on the cell.
ALWAYS test and adjust water balance, before attempting scale control via
shortening reverse period.
(CONTINUED)
allows manual control forward and back. While in this feature, pressing MENU will override
Continued Next Page...