Philips VARI-LITE VL6000 Beam Luminaire User Manual page 89

Hide thumbs Also See for VARI-LITE VL6000 Beam Luminaire:
Table of Contents

Advertisement

Message
Symptom
n/a
Lamp douses frequently
n/a
Lamp will not strike
n/a
Luminaire behaves oddly
n/a
Luminaire does not power
up
n/a
Self tests will not run or
software download does
not work from luminaire.
n/a
No response to DMX data
n/a
Erratic control of luminaire
02.97 08.000 2
T
Description
Lamp Douse
Lamp Strike Failure
DMX Map Not Matched
No power
DMX Data Input
DMX Failure
DMX Termination
2 7 Ap ril 2 017
ROUBLESHOOTING AND
Possible Cause/Remedy
Fan failure...
- check head and enclosure fans for proper operation.
Ballast overheating...
- operating within the specified ambient temperature?
- check enclosure vents for debris / dirt.
- check fan settings in menu.
- check enclosure fans for proper operation.
NOTE: Upon initial power up, ballast fans will run for a few
seconds and then operate as needed. Enclosure vents
must be clear of debris and dirt to allow proper airflow.
Lamp cutout switch disengaged...
- check lamp cutout switches at lamp box and fan ducts.
Bad lamp...
- replace lamp.
Low input voltage...
- check input power (must be 200 to 240 VAC).
Fan failure...
- check head and enclosure fans for proper operation.
Console library not set correctly...
- check console library matches DMX map of luminaire.
Circuit not energized...
- verify circuit breaker (at source) is turned on.
Not plugged in...
- ensure A/C cable is connected to power source.
Detecting DMX data...
- disconnect DMX input cable.
DMX connector disconnected...
- check DMX DATA IN connection.
No DMX termination or termination not correct...
- check for DMX terminator.
- Luminaire DMX address does not match console patch.
A
M
AINTENANCE
71

Advertisement

Table of Contents
loading

Table of Contents