Sony BVM-1911 Operation And Maintenance Manual page 40

Trinitron color video monitor
Table of Contents

Advertisement

C:
0
~
Q)
C.
0
.,..:
Section 1 Operation
1
.3511.
Operation
2
Move the cursor to REMOTE CONTROL and press the ENT
button.
The REMOTE CONTROL MENU is displayed.
REMOTE CONTROL MENU
• SERIAL REMOTE
STANDARD PARALLEL
CONFIGURE PARALLEL
SELECT AND PRESS ENT
Note that SERIAL REMOTE is for future use.
3
To change the pin assignment of the REMOTE connector,
move the cursor to CONFIGURE PARALLEL and press the ENT
button.
To resume the factory-set pin assignment, move the cursor to
ST AND ARD PARALLEL and press the ENT button. (For the
factory-set pin assignment, see page 1-34.)
The following display appears.
REMOTE CONTROL MENU
WARNING II
HARDWARE CHANGE REQUIRED
PLEASE CONSULT MANUAL
Hardware Change
PRESS ENT TO CONFIRM OR
ESCTO QUIT
When using ST AND ARD PARALLEL or CONFIGURE PARALLEL
mode, the 8-pin connector must be connected to HY-4 of the HY
board in the drawer. Although it must have been done at the factory,
make sure that the connector is connected to HY-4 properly.
If
not,
remove the connector from HY-2 and connect it to HY-4.
4
Press the ENT button again to confirm the mode change in step 3.
When STANDARD PARALLEL has been selected in step 3, the
selected mode is now activated and the monitor returns to normal
status.
When CONFIGURE PARALLEL has been selected, the CONFIG
PARALLEL REMOTE menu is displayed.
CONFIG PARALLEL REMOTE
•PIN
1
MONO
PIN 2
INPUT SEL 2/1
PIN 4
SYNC
PINS
PIN 6
VITC
PIN 7
MARKER MOVE
SAVE AND APPLY
PIN 3 TALLY
PIN 8 GND
SELECT AND PRESS ENT