Cleaning and maintenance
48/62
5.18

AQUA / AROMA SYSTEM maintenance

The AQUA SYSTEM function sprays a fine mist of AQUA SOLAR WITH
SKIN+ ADDITIVE into the interior of the device for body cooling (see 'AQUA
SYSTEM PRODUCT INFORMATION', order no. 1011201-..).
DANGER!
Customer health hazard!
Water that has been contaminated with bacteria can cause
skin rashes and other allergic reactions in device users.
Therefore you must never fill the AQUA SYSTEM canis-
ter with tap water or other liquids.
Only replace the AQUA SYSTEM canister with a genu-
ine canister.
Do not add any liquid that remains in the old canister to
the new canister!
Ensure that the maximum temperature specified is not
exceeded during transport and storage.
Note the expiry date on the canister.
The AQUA / AROMA SYSTEM also includes the fragrance 'BEAUTY
HEAVEN' which is distributed via the head nozzles as well as in the cabin.
Other fragrances are also available. Contact JK-International GmbH, Division
JK-Licht for further details (see page 2).
5.18.1

Changing the AROMA canister

Opening the bed base: see page 38.
Remove the AROMA canister.