Rohs; Other Approvals; Emc And Environmental Type Tests - Siemens RUGGEDCOM RS900W Installation Manual

Wireless ethernet switches
Table of Contents

Advertisement

RUGGEDCOM RS900W
Installation Guide
Section 6.1.5

RoHS

This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
• China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
view/109738831.
Section 6.1.6

Other Approvals

This device meets the requirements of the following additional standards:
• IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
• IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments
• IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General Requirements
Section 6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS900W has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
RoHS
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
https://support.industry.siemens.com/cs/ww/en/
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Signal Ports
± 4 kV Line-to-Ground
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
± 2 kV
Chapter 6
Certification
Severity Levels
4
4
x
x
4
4
4
4
31