Main Assembly 12 (Case Unit); Near-End Detector Assembly (Optional) - Casio UP-250 Technical Manual

External printer
Hide thumbs Also See for UP-250:
Table of Contents

Advertisement

Main Assembly 12 (Case Unit)

Near-end detector assembly (optional)

1. Attach the near-end detector lever to the near-end detector frame.
2. Connect the lead wire assembly's connector to the near-end detector and attach it to the
near-end detector frame with the screw.
Lead wire assembly
3. Decide whether you want to install the spacers.
The amount (A) of paper remaining (including the paper roll core) when the near-end
detector senses a paper near-end is changed by the spacers.
The amount (A) with the spacers: 3 to 4 mm (0.12 to 0.16")
The amount (A) with the spacers: 6 mm (0.24")
The value of (A) is obtained by calculation only. Therefore, it may not be appropriate for all
printers.
Near-end detector
lever
d
— 132
CBB-tite (M2x8)
[0.1 to 0.2 N • m
(1 to 2 kgf • cm)]
Near-end detector
Near-end detector
frame
A