Main Assembly 5 (Case Unit)

Lower case assembly

1. Attach the lower case to the printer mechanism assembly. It is easy to assemble if you first
place portion B of the lower case under portion A of the upper plate.
2. Bring out the paper feed motor and carriage motor cables through portion C and the sensor
assembly lead wires through portion D.
3. Secure the lower case with the screws.
[Adjustment] Perform the platen gap adjustment by referring to the Adjustment section at the end of
this chapter .
CPT-B (M3x12)
[0.59 to 0.78 N • m
[6 to 8 kgf • cm)]
Auto-cutter assembly's lead wires
Lower case
Portion C
Portion D
Portion A