Torque Sequence - Graco Husky 515 Instructions Manual

Air operated diaphragm pumps acetal, polypropylene, and pvdf model no. d51 acetal npt pumps* model no. d52 polypropylene pumps model no. d55 pvdf npt pumps model no. d5a acetal bspt pumps* model no. d5b polypropylene bspt pumps model no. d5e pvdf
Hide thumbs Also See for Husky 515:
Table of Contents

Advertisement

Always follow torque sequence when instructed to torque fasteners.
Husky 515
1. Left/Right Fluid Covers
Torque bolts to 80–90 in–lb (9–10 NSm)
3
1 1 1 1
8 8
6
4
2
SIDE VIEW
2. Inlet Manifold
Torque bolts to 80–90 in–lb (9–10 NSm)
11
10
9
12
BOTTOM VIEW
3. Outlet Manifold
Torque bolts to 80–90 in–lb (9–10 NSm)
13
16
15
14
TOP VIEW

Torque Sequence

5
7
Husky 716
1. Left/Right Fluid Covers
Torque bolts to 80–90 in–lb (9–10 NSm)
2
FRONT VIEW
2. Inlet Manifold
Torque bolts to 80–90 in–lb (9–10 NSm)
5
3
4
4
6
6
BOTTOM VIEW
3. Outlet Manifold
Torque Bolts to 80–90 in–lb (9–10 NSm)
9
7
8
10
TOP VIEW
1
308981
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Husky 716Husky 515 seriesHusky 716 series

Table of Contents