Graco Husky 515 Instructions Manual page 14

Air operated diaphragm pumps acetal, polypropylene, and pvdf model no. d51 acetal npt pumps* model no. d52 polypropylene pumps model no. d55 pvdf npt pumps model no. d5a acetal bspt pumps* model no. d5b polypropylene bspt pumps model no. d5e pvdf
Hide thumbs Also See for Husky 515:
Table of Contents

Advertisement

Ball or Duckbill Check Valves
NOTE: Fluid Section Repair Kit D05XXX is available.
See page 21 to order the correct kit for your pump.
Parts included in the kit are marked with a double
dagger (}) in Fig. 7 and Fig. 8 and in the Parts Draw-
ings and Lists. General purpose grease 111920 and
Adhesive 113500 are supplied in the kit.
1. Relieve the pressure. See
Pressure Relief Procedure on
page 10.
2. Remove the top and bottom manifolds (102, 103).
3. Remove all parts shown with a dagger (}) in Fig. 7
and Fig. 8.
4. Clean all parts, and replace worn or damaged
parts.
5. Reassemble the pump.
NOTE: Torque the manifold nuts (109) or bolts
(105) to 80 to 90 in-lb (9 to 10 NSm). See Torque
Sequence, page 27.
14
308981
Service
Inlet and Outlet for Pumps with Duckbill
Check Valves
Pumps with duckbill check valves are shipped with the
inlet manifold on top and the outlet manifold on the
bottom. To make the inlet manifold on the bottom and
the outlet manifold on the top, rotate each of the four
duckbill assemblies vertically 180_ as shown below.
}
139
}
201
9080A
}
202

Advertisement

Table of Contents
loading

This manual is also suitable for:

Husky 716Husky 515 seriesHusky 716 series

Table of Contents