Emerson ACF552ORB00 Owner's Manual
Emerson ACF552ORB00 Owner's Manual

Emerson ACF552ORB00 Owner's Manual

Verandah 132 cm (52 inch) net weight: 9.8 kg

Advertisement

Quick Links

READ AND SAVE THESE INSTRUCTIONS
VERANDAH
132 cm (52") Ceiling Fan
MOST IMPORTANT: READ THESE INSTRUCTIONS
THE FAN MUST BE INSTALLED BY A LICENSED ELECTRICIAN.
This ceiling fan is imported by MyFan as an agent for the USA design owners' and can provide
after sales service for this product if required. Contact can be made by phone, fax or email
during normal trading hours. Copies of owner's manuals for each model can be found on our
web site.
Part No. F40BP74610000
Owner's Manual
ACF552ORB00
ACF552WW00
Net Weight:
(The warranty on this fan will be void if the appliance
is not installed by a licensed electrician).
Phone: 1300 469 326
info@myfan.com.au
www.myfan.com.au
Models
9.8
Kg.
Form No. BP7461
Model No.: ACF552

Advertisement

Table of Contents
loading

Summary of Contents for Emerson ACF552ORB00

  • Page 1 READ AND SAVE THESE INSTRUCTIONS VERANDAH ™ 132 cm (52”) Ceiling Fan Owner's Manual Models ACF552ORB00 ACF552WW00 Net Weight: MOST IMPORTANT: READ THESE INSTRUCTIONS THE FAN MUST BE INSTALLED BY A LICENSED ELECTRICIAN. (The warranty on this fan will be void if the appliance is not installed by a licensed electrician).
  • Page 2: Safety Instructions

    WARNING WARNING To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at fuse box and lock to prevent power from being switched on accidentally.
  • Page 3: Tools Needed For Assembly

    THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS. USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS. This manual is designed to make it as easy as possible for your Electrician to assemble and install your ceiling fan.
  • Page 4 How to Put This Ceiling Fan Together 1. Remove the hanger ball by loosening the setscrew WARNING in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely downrod, then remove the hanger ball.
  • Page 5 7. The motor lead wires will require shortening if 11. Loosely attach one blade assembly to the motor using a 1.5 m. or shorter downrod. The fan comes hub using two M6 x 14 captive pan head screws with blue, brown, orange and green/yellow motor with lockwashers installed on the fan blade leads that are 2 m.
  • Page 6: Electrical And Structural Requirements

    15. Connect the ceiling fan wire connector to the Electrical and Structural switch cup wire connector (Figure 9). Requirements 16. Remove the M4 x 12mm flat head switch cup cover screws (reserve for future use) (Figure 9). This new ceiling fan will require a grounded electrical supply line of 240V, AC, 50Hz, 10 amp circuit.
  • Page 7: How To Hang This Ceiling Fan

    How To Hang This Ceiling Fan WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. WARNING The fan must be hung with at least 2.1 meters of WARNING clearance from floor to blades (Figure 12). To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and CEILING...
  • Page 8: Final Installation

    Final Installation WARNING Protruding bare wire or wire strands at the terminal 1. Screw the two #8-32 x 1-1/4” threaded studs block creates the possibility of an electrical shock. Do (supplied) into the tapped holes in the hanger not operate the fan until the terminal block connections are completely enclosed within the insulated terminal bracket (Figure 17).
  • Page 9: Troubleshooting

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
  • Page 10: Repair Parts

    Repair Parts Maintenance IMPORTANT CARE INSTRUCTIONS Abrasive cleaning agents are not required and should for your Ceiling Fan be avoided to prevent damage to finish. Periodic cleaning of your new ceiling fan is the only WARNING maintenance that is needed. When cleaning, use only a soft brush or lint free cloth Do not use water when cleaning your ceiling fan.
  • Page 11: Energy Efficient Use Of Ceiling Fans

    Ceiling fan performance and energy savings Model No. Model No. rely heavily on the proper installation and use Description ACF552ORB00 ACF552WW00 of the ceiling fan. Here are a few tips to ensure quality and product performance. Hanger Ball Assembly, 761655-32...
  • Page 12: Section 1: What To Do If Your Fan Has A Problem

    Air Comfort Products 1300 469 326 (07) 3801 8575 info@myfan.com.au My Fan Pty Ltd DIVISION OF EMERSON ELECTRIC CO. PO Box 6560 8100 W. Florissant • St. Louis, MO 63136 Visit us online at www.myfan.com.au GCMC QLD 9726 Part No. F40BP74610000 Form No.

This manual is also suitable for:

Acf552ww00

Table of Contents