TEST SETUP & TESTING
Any level 3 repairs can deeply affect the performance of the MTM800 ENH
!
!
terminal and may cause a new tuning procedure.
This tuning procedure can only be applied by certain authorized Motorola
W A R N I N G
depots where the appropriate TEST&TUNE EQUIPMENT is available.
The appropriate TEST&TUNE EQUIPMENT is a special automated test
equipment which is only available at some Motorola factories and Motorola
repair centers.
Typical Test Setup
Before Testing
Carry out the following instructions before testing:
•
Connect the DC cable to the DC connector on the terminal.
•
Connect the other side of the DC cable to the DC output connector on the power supply
•
Connect an RF cable to the N-type RF Connector of the IFR.
•
Connect the other side of the RF cable to the antenna connector on the terminal.
•
Set the DC voltage on the power supply to 13.2 Volts.
•
Switch on the terminal.
TEST SETUP & TESTING
Figure 6-1 Typical Test Setup
6 - 1
CHAPTER 6