Spraying
Manual Hose Heat Mode
If the system produces the T6DH sensor error hose
alarm or the T6DT sensor error TCM alarm, use
manual hose heat mode until the hose RTD cable or
FTS temperature sensor can be repaired.
Do not use Manual Hose Mode for extended periods
of time. The system performs best when the hose
has a valid RTD and can operate in temperature
control mode. If a hose RTD breaks, the first priority
is to fix the RTD. Manual Hose Mode can help finish
a job while waiting for repair parts.
Enable Manual Hose Mode
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
48
3. Select Enable Manual Hose Mode.
Note
When manual hose mode is enabled, the
manual hose mode advisory EVCH-V
will appear.
4. Enter Run Mode and navigate to the Target
screen. Use the up and down arrows to set the
desired hose current.
Hose Current Settings Hose Current
Default
Maximum
20A
37A
333023D