Supply Wet Cups With Throat Seal Liquid; (Tsl); Install Fluid Temperature Sensor; Register And Activate The Graco Insite - Graco Reactor 2 E-XP2 Operation

Proportioning systems
Hide thumbs Also See for Reactor 2 E-XP2:
Table of Contents

Advertisement

Supply Wet Cups With Throat Seal
Liquid (TSL)
Pump rod and connecting rod move during
operation. Moving parts can cause serious injury
such as pinching or amputation. Keep hands and
fingers away from wet-cup during operation.
To prevent the pump from moving, turn the main
power switch OFF.
• Component A (ISO) Pump: Keep reservoir (R) filled
with Graco Throat Seal Liquid (TSL), Part 206995.
Wet-cup piston circulates TSL through wet-cup, to
carry away isocyanate film on displacement rod.
Figure 9 Component A Pump
333023D
• Component B (Resin) Pump: Check felt washers
in packing nut/wet-cup (S) daily. Keep saturated
with Graco Throat Seal Liquid (TSL), Part No.
206995, to prevent material from hardening on
displacement rod. Replace felt washers when worn
or contaminated with hardened material.
Figure 10 Component B Pump

Install Fluid Temperature Sensor

The Fluid Temperature Sensor (FTS) is supplied.
Install FTS between main hose and whip hose. See
Heated Hose manual for instructions.

Register and Activate the Graco InSite

Note
Elite systems only.
1. Go to www.GracoInSite.com, then follow the
instructions on the screen.
2. Find and record the 15 digit serial number from
the cellular module below.