Power Supplies; Components - Dell S6100 Installation Manual

On system
Hide thumbs Also See for S6100:
Table of Contents

Advertisement

The S6100–ON supports AC or DC power supplies with two air-flow directions, normal and reverse. Normal airflow is from the I/O to the
PSU and reverse airflow is from the PSU to the I/O.
Two PSUs are required for full redundancy, but the system can operate with a single PSU. To protect against high-voltage shock, install a
power supply blank in all unused power supply slots.
The PSU is field replaceable. When running with full redundancy—two power supplies installed and running, you can remove and replace
one PSU without disrupting traffic.
CAUTION:
To prevent electrical shock, ensure that the S6100-ON is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical
requirements.
NOTE:
Connect the power supply to the appropriate branch circuit protection as defined by your local electrical codes. Verify
that the remote power source complies with the system input power specifications.
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S6100–ON and its components.
Topics:

Components

AC or DC power supply installation
AC or DC power supply replacement
Components
The following power supply options are available for the S6100–ON:
AC or DC power supply with integrated fan
AC or DC power supply with integrated reverse flow fan
Both PSUs are on the right side of the switch. Power supply 1, PSU1, is on the top of the chassis; power supply 2, PSU2, is on the bottom
of the chassis.
Figure 24. S6100–ON PSUs

Power supplies

Power supplies
6
33