Before Installing Faxfinder; Mounting Faxfinder (Optional); Rack Safety; Mounting Faxfinder In A 19-Inch Rack - Multitech FF-240 Hardware And Installation Manual

Hide thumbs Also See for FF-240:
Table of Contents

Advertisement

HARDWARE AND INSTALLATION

Before Installing FaxFinder

Disable Call Waiting on lines or PBX ports to be used with FaxFinder. FaxFinder does not support Call Waiting. The
Call Waiting beep causes fax communication errors.

Mounting FaxFinder (Optional)

The FaxFinder 240-IP is a table-top unit that can be wall- or rack-mounted. Mounting kits can be purchased
separately.
When installing the unit in a closed or multi-unit enclosure, follow the recommended installation defined by the
enclosure manufacturer.
Note:
The images in this section show a different FaxFinder model. The dimensions and mounting instructions
are the same.

Rack Safety

When installing the unit in a closed or multi-unit enclosure, follow the recommended installation defined by the
enclosure manufacturer.
Note:
The ambient temperature of the rack interior must not exceed 40° Celsius.
Do not place the unit directly on top of other equipment or place other equipment directly on top of the
unit.
If installing the unit in a closed or multi-unit enclosure, ensure adequate airflow within the rack so that the
maximum recommended ambient temperature (40° C) is not exceeded.
Ensure that the unit is properly connected to earth ground by verifying that it is reliably grounded when
mounted within a rack.
If a power strip is used, ensure that the power strip provides adequate grounding of the attached
apparatus.
When mounting the equipment in the rack, make sure mechanical loading is even to avoid a hazardous
condition. The rack should safely support the combined weight of all the equipment it supports.
Ensure that the main supply circuit is capable of handling the load of the equipment. See the power label on
the equipment for load requirements.
Only properly qualified service personnel should install this equipment. Only connect like circuits - connect
SELV (Secondary Extra Low Voltage) circuits to SELV circuits and TN (Telecommunications Network) circuits
to TN circuits.

Mounting FaxFinder in a 19-inch Rack

Use these steps to mount FaxFinder in a 19-inch rack enclosure.
18
®
FaxFinder
Fax Server FF-240, FF-440, FF-840, FF240-IP Hardware and Installation Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ff-440Ff-840Ff240-ip

Table of Contents