SMA Solar Technology AG
Procedure:
1. Activate the user interface (see Section 8.1, page 43).
2. Log into the user interface (see Section 8.2, page 46).
3. Select the menu Device Configuration.
4. Select [Settings].
5. In the context menu, select [Saving the configuration in a file].
6. Follow the instructions in the dialog.
9.8
Adopting a Configuration from a File
To configure the inverter, you can adopt the configuration from a file. To be able to do this, you
must first save the configuration of another inverter in a file (see Section 9.7 "Saving the
Configuration in a File", page 54). When saving, only the device parameters will be adopted, not
any passwords.
Requirements:
☐ The SMA Grid Guard code must be available (see "Application for SMA Grid Guard Code"
at www.SMA-Solar.com).
☐ Changes to grid-relevant parameters must be approved by the responsible grid operator.
Procedure:
1. Activate the user interface (see Section 8.1, page 43).
2. Log into the user interface as an Installer.
3. Select the menu Device Configuration.
4. Select [Settings].
5. In the context menu, select [Adopting the configuration from a file].
6. Follow the instructions in the dialog.
9.9
Activate WPS Function
• Activate the WPS function on the inverter. To do this, tap on the enclosure lid of the inverter
twice.
☑ The blue LED flashes quickly for approx. two minutes. The WPS function is active.
9.10 Activating the Receipt of Control Signals (Only for
Italy)
In order for PV systems in Italy to receive control commands from the grid operator, set the
following parameters.
Operating Manual
9 Configuration of the Inverter
SB15-25-1VL-40-BE-en-11
55