Chapter 4. Specifications
4.1 General Specifications
The general specifications for the Model XGM868i flow transmitter are as follows:
4.1.1 Hardware Configuration
4.1.1a
Enclosures:
Standard: Epoxy-coated aluminum Type 4X/IP66
Class 1, Division 1, Groups B C and D
Flameproof ISSeP 02ATEX008
II 2GD EE d IIC T5 IP66 T95°C
Optional: Stainless steel
4.1.1b
Physical:
Size: 8.2 in. long x 6.6 in. diameter (208 x 168 mm)
Weight: Al = 10 lb (4.5 kg), SS = 30 lb (13.6 kg)
4.1.2 Environmental
4.1.2a
Operating Temperature:
–40° to 140°F (–40° to 60°C)
4.1.2b
Storage Temperature:
–67° to 167°F (–55° to 75°C)
4.1.3 Velocity Accuracy
4.1.3a
% of Reading:
1% to 2% of reading typical
Note: Accuracy depends on pipe size and other factors, such as 1-path or 2-path measurement. Accuracy to ±0.5% of
reading may be achievable with process calibration.
DigitalFlow™ XGM868i Startup Guide
Chapter 4. Specifications
55