Removing and Inspecting Cooler

WARNING
HOT SURFACE HAZARD
Be sure the compressor duct work is
cool before removing it. If the sprayer
was operated recently, it will be very hot
and can cause burns.
Fig. 20
22
308718
See Fig. 20
1.
2. Loosen the clamp (28) on the hose (29), and
remove the hose from the cooler (27).
3. Remove the screws (7) and cooler (27). Clean the
cooler, and inspect for leaks, dents, or plugging
with dust.
28
27
A
29
A
Relieve the pressure.
See Pressure Relief
Procedure on page 5.
7
7082B