Self-Diagnosis Code Table - Sony HDR-SR11 Service Manual

Digital hd video camera recorder
Hide thumbs Also See for HDR-SR11:
Table of Contents

Advertisement

1-2-3. Self-diagnosis Code Table

Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
C
1
3
0
C
1
3
0
C
3
2
6
E
2
0
0
E
3
1
0
E
6
1
1
E
6
1
1
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
1
E
6
2
1
E
6
2
1
E
6
2
2
E
9
1
0
E
9
4
0
Note 1 : Refer to Service Manual, ADJ ("1-3. DESTINATION DATA WRITE").
Note 2 : When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
HDR-SR11/SR11E/SR12/SR12E_L2
Symptom/State
0
Non-standard battery is used.
"Memory Stick Duo" is unformatted.
1
"Memory Stick Duo" is broken.
2
Disc access error
Difficult to adjust focus
0
(Cannot initialize focus)
0
Flash memory data are rewritten.
0
Drive fault
Zoom operations fault
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
1
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
0
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
1
work well. (With YAW angular velocity
sensor output stopped.)
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
3
communication abnormality among.
0
Shift lens initializing failure.
Shift lens overheating (Pitch)
1
Shift lens overheating (Yaw)
2
0
Abnormality of thermistor.
1
Abnormality when flash is being charged.
Fault of writing or erasing the
0
flash memory
Use the InfoLITHIUM battery.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Remove the power source. Reconnect it again and operate your
camcorder again
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin w;, wa of
CN5103 on the LD-230 board). If it is OK, check the focus
motor drive IC (IC5201 on the LD-230 board).
Make flash memory data correct value. (Note 1)
Inspect or replacement of the hard disk drive.
Inspect the lens block zoom MR sensor (pin qh, qj of CN5103
on the LD-230 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5201 on the LD-230 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE9001 on the FR-278
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE9002 on the FR-278
board) peripheral circuits.
Refer to [1-3-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5501 on the LD-230 board).
Replacement of lens block. If an error occurs again, replace the
LD-230 board. (Note 2)
Refer to [1-3-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-3-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-3-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-516 board).
1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdr-sr11eHdr-sr12eHdr-sr12Rmt-835

Table of Contents