barbas CUATRO-3 75 Installation Instructions & Manual For Annual Maintenance page 37

Wood-burning insert/built-in appliance
Table of Contents

Advertisement

CUATRO-3 75
Appliance:
1
Inlet opening combustion air (front of appliance, bottom, 2x
Important:
dismount 2x "closed" discs (left and right of the combustion air-supply slider)
and mount 2x "open" discs with opening;
1 is stated on the drawing.)
2
Inlet opening combustion air (bottom of appliance, Ø125 mm) / (air-box,
Ø125 mm) / (fan box, Ø125 mm).
3
Inlet opening convection air (front of appliance, bottom, 2x
Important:
dismount 2x "closed" discs (left and right of the combustion air-supply slider)
and mount 2x "open" discs with opening;
3 is stated on the drawing.)
4
Inlet opening convection air (bottom of appliance,
(fan box, Ø125 mm)
5
Flue connection (topside of appliance, Ø200 mm)
6
Outlet opening convection air (front of appliance, above)
7
Outlet opening convection air (top of appliance) / (Connection convection set)
(2x or 4x Ø125 mm)
Important:
Remove "break-away" discs (2x or 4x Ø125 mm)! (Only valid when 7 is stated on
the drawing.)
8
Insulation material, noninfl ammable ‼! (for example ceramic fi bre) (sides and top
of appliance)
Chimney / Chimney breast:
9
Inlet opening combustion air/convection air/chimney-ventilation air (grate,
bottom of chimney)
10
Outlet opening convection air/chimney-ventilation air (grate, top of chimney)
11
Outlet opening convection air via convection set (grate, top of chimney)
Exterior wall:
12
Inlet opening combustion air (grate, exterior wall).
Installation instructions
37 x 150 mm).
37x150 mm. (Only valid when
37 x 97 mm.)
37 x 97 mm. (Only valid when
20 x 480 mm) /