GE 869 Communications Manual page 44

Motor protection system, control and management
Hide thumbs Also See for 869:
Table of Contents

Advertisement

INTEROPERABILITY
6-4
Number / description
□ <31> := Double-point information with time tag CP56Time2a
□ <32> := Step position information with time tag CP56Time2a
□ <33> := Bitstring of 32 bits with time tag CP56Time2a
□ <34> := Measured value, normalized value with time tag CP56Time2a
⊠ <35> := Measured value, scaled value with time tag CP56Time2a
□ <36> := Measured value, short floating point value with time tag CP56Time2a M_ME_TF_1
⊠ <37> := Integrated totals with time tag CP56Time2a
□ <38> := Event of protection equipment with time tag CP56Time2a
□ <39> := Packed start events of protection equipment with time tag
CP56Time2a
□ <40> := Packed output circuit information of protection equipment with time
tag CP56Time2a
Table 6-2: Process information in control direction
Number / description
⊠ <45> := Single command
⊠ <46> := Double command
□ <47> := Regulating step command
□ <48> := Set point command, normalized value
□ <49> := Set point command, scaled value
□ <50> := Set point command, short floating point value
□ <51> := Bitstring of 32 bits
⊠ <58> := Single command with time tag CP56Time2a
⊠ <59> := Double command with time tag CP56Time2a
□ <60> := Regulating step command with time tag CP56Time2a
□ <61> := Set point command, normalized value with time tag CP56Time2a
□ <62> := Set point command, scaled value with time tag CP56Time2a
□ <63> := Set point command, short floating point value with time tag
CP56Time2a
□ <64> := Bitstring of 32 bits with time tag CP56Time2a
Either the ASDUs of the set <45> to <51> or of the set <58> to <64> are used.
Table 6-3: System information in monitor direction
Number / description
⊠ <70> := End of initialization
Table 6-4: System information in control direction
Number / description
⊠ <100> := Interrogation command
⊠ <101> := Counter interrogation command
⊠ <102> := Read command
⊠ <103> := Clock synchronization command (see Clause 7.6 in standard)
⊠ <105> := Reset process command
⊠ <107> := Test command with time tag CP56Time2a
869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 6: IEC 60870-5-104
Mnemonic
M_DP_TB_1
M_ST_TB_1
M_BO_TB_1
M_ME_TD_1
M_ME_TE_1
M_IT_TB_1
M_EP_TD_1
M_EP_TE_1
M_EP_TF_1
Mnemonic
C_SC_NA_1
C_DC_NA_1
C_RC_NA_1
C_SE_NA_1
C_SE_NB_1
C_SE_NC_1
C_BO_NA_1
C_SC_TA_1
C_DC_TA_1
C_RC_TA_1
C_SE_TA_1
C_SE_TB_1
C_SE_TC_1
C_BO_TA_1
Mnemonic
M_EI_NA_1
Mnemonic
C_IC_NA_1
C_CI_NA_1
C_RD_NA_1
C_CS_NA_1
C_RP_NA_1
C_TS_TA_1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents