CHAPTER 11: MODBUS MEMORY MAP
Modbus
Hex
Description
Address
Address
81393
0xA1B0
Block
81395
0xA1B2
HI 1 Output Relays
81397
0xA1B4
EQL 1 Output Relays
81399
0xA1B6
LO 1 Output Relays
81401
0xA1B8
Events
Digital Counter 2
81402
0xA1B9
Function
81403
0xA1BA
Name
81416
0xA1C7
Units
81419
0xA1CA
Pre-set
81421
0xA1CC
Compare
81423
0xA1CE
Up
81425
0xA1D0
Down
81427
0xA1D2
Set to Pre-set
81429
0xA1D4
Reset
81431
0xA1D6
Freeze/Reset
81433
0xA1D8
Freeze/Count
81435
0xA1DA
Block
81437
0xA1DC
HI 2 Output Relays
81439
0xA1DE
EQL 2 Output Relays
81441
0xA1E0
LO 2 Output Relays
81443
0xA1E2
Events
Digital Counter 3
81444
0xA1E3
Function
81445
0xA1E4
Name
81458
0xA1F1
Units
81461
0xA1F4
Pre-set
81463
0xA1F6
Compare
81465
0xA1F8
Up
81467
0xA1FA
Down
81469
0xA1FC
Set to Pre-set
81471
0xA1FE
Reset
81473
0xA200
Freeze/Reset
81475
0xA202
Freeze/Count
81477
0xA204
Block
81479
0xA206
HI 3 Output Relays
81481
0xA208
EQL 3 Output Relays
81483
0xA20A
LO 3 Output Relays
81485
0xA20C
Events
Digital Counter 4
81486
0xA20D
Function
81487
0xA20E
Name
81500
0xA21B
Units
81503
0xA21E
Pre-set
81505
0xA220
Compare
81507
0xA222
Up
869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
Min
Max
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
-2147483648 2147483647 1
-2147483648 2147483647 1
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
-2147483648 2147483647 1
-2147483648 2147483647 1
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
-2147483648 2147483647 1
-2147483648 2147483647 1
0
0xFFFFFFFF
Step Units
Format
Code
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 2
1
F60_6
F30
F30
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 3
1
F60_6
F30
F30
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 4
1
F60_6
F30
F30
1
FC142
MODBUS MEMORY MAP
Factory
Size in
Default
Words
0
1
0
1
0
1
0
1
1
1
0
1
26
units
6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
26
units
6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
26
units
6
0
1
0
1
0
1