GE 869 Communications Manual page 237

Motor protection system, control and management
Hide thumbs Also See for 869:
Table of Contents

Advertisement

CHAPTER 11: MODBUS MEMORY MAP
Modbus
Hex
Description
Address
Address
81849
0xA378
Reset
81851
0xA37A
Freeze/Reset
81853
0xA37C
Freeze/Count
81855
0xA37E
Block
81857
0xA380
HI 12 Output Relays
81859
0xA382
EQL 12 Output Relays
81861
0xA384
LO 12 Output Relays
81863
0xA386
Events
Digital Counter 13
81864
0xA387
Function
81865
0xA388
Name
81878
0xA395
Units
81881
0xA398
Pre-set
81883
0xA39A
Compare
81885
0xA39C
Up
81887
0xA39E
Down
81889
0xA3A0
Set to Pre-set
81891
0xA3A2
Reset
81893
0xA3A4
Freeze/Reset
81895
0xA3A6
Freeze/Count
81897
0xA3A8
Block
81899
0xA3AA
HI 13 Output Relays
81901
0xA3AC
EQL 13 Output Relays
81903
0xA3AE
LO 13 Output Relays
81905
0xA3B0
Events
Digital Counter 14
81906
0xA3B1
Function
81907
0xA3B2
Name
81920
0xA3BF
Units
81923
0xA3C2
Pre-set
81925
0xA3C4
Compare
81927
0xA3C6
Up
81929
0xA3C8
Down
81931
0xA3CA
Set to Pre-set
81933
0xA3CC
Reset
81935
0xA3CE
Freeze/Reset
81937
0xA3D0
Freeze/Count
81939
0xA3D2
Block
81941
0xA3D4
HI 14 Output Relays
81943
0xA3D6
EQL 14 Output Relays
81945
0xA3D8
LO 14 Output Relays
81947
0xA3DA
Events
Digital Counter 15
81948
0xA3DB
Function
81949
0xA3DC
Name
81962
0xA3E9
Units
869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
Min
Max
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
-2147483648 2147483647 1
-2147483648 2147483647 1
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
-2147483648 2147483647 1
-2147483648 2147483647 1
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
0xFFFFFFFF
0
1
0
1
0
65535
0
65535
Step Units
Format
Code
1
FC142
1
FC142
1
FC142
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 13 26
1
F60_6
F30
F30
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 14 26
1
F60_6
F30
F30
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC142
1
FC198
1
FC198
1
FC198
1
FC126
1
FC126
1
F60_26 Counter 15 26
1
F60_6
MODBUS MEMORY MAP
Factory
Size in
Default
Words
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
units
6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
units
6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
units
6
11-143

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents