Wiring The Main Control Board I/O Terminals - AB Quality PowerFlex 700S Quick Start Manual

Table of Contents

Advertisement

Wiring the Main Control Board I/O Terminals

Terminal blocks TB1 and TB2 contain connection points for all inputs,
outputs and standard encoder connections. Both terminal blocks reside on
the Main Control Board.
Remove the terminal block plug from the socket, and make connections.
TIP: Remember to route wires through the sliding access panel at the
bottom Control Assembly.
Reinstall the plug, when wiring is complete. The terminal blocks have keys,
which make it difficult to insert a terminal plug into the wrong socket.
Table F Control & Encoder Terminal Block Specifications
Name
I/O & Encoder
Blocks
(1) Maximum/minimum sizes the terminal block will accept - these are not recommendations.
Figure 1 Main Control Board I/O Terminal Locations
TB1 - Row T (Top)
TB2 - Row T (Top)
Frame
Description
1, 2, 3, 5 Signal & Encoder
power connections
PowerFlex® 700S Drive
(1)
Wires Size Range
Torque
Maximum
Minimum
Maximum
2
2
1.5 mm
.14 mm
.25 N-m
(16 AWG)
(28 AWG)
(2.2 lb.-in.)
17
Recommended
.22 N-m
(1.9 lb.-in.)
TB1 - Row B (Bottom)
TB2 - Row B (Bottom)