g. CLMON signal
This signal monitors the CL output voltage. ON (lighted) at HIGH, and
OFF at LOW.
h. CLPR signal
This signal controls the power relay (S701) in the AC input section.
ON at HIGH, and OFF at LOW. When the CL voltage becomes an
overvoltage, the power relay is turned off even through the CLPR is
LOW.
F701
PWB A
125V/15A
(CN701)
F709
L729
125V/4A
S701
CL300-300FD
(L)
AJW4512
CN709-1
(N)
CN709-2
[Waveform of each section]
Fig. 42 IC712
Fig. 43 C7016 voltage (duty 100%)
T704
N-T01-014
R7049
1K(1/2W)
R7050
1K(1/2W)
D765
RD16ESAB2
PC708
Primary side
R7040
TR702
1K
BCR8PM8
FA702
6.0/115
R7038
C791
470K
0.047(PA)
(1/4W)
3.1V
Condition: Input 100VAC
0V
8.5V
5
pin voltage
0V
PC707
R7092
4.7K
PS2561
Secondary side
PC707
R7082
Q718
8.2K
2SA1020
PS2561
R7081
10K
R7086
4.7K
VR704
5KB
R7083
3.9K
R7084
3.9K
CL voltage
VR705
adjustment
10KB
D777
1SS178
Fig. 44 C7016 voltage (duty 20%)
Fig. 45 Q714 drain-source voltage waveform
9 – 31
R7101
R7103
2.2K
4.7K
CLMON CN710-1
Lighting H
Lighting LO
RET (MAIN PWB)
CN707-2
R7092
R7101
R7103
4.7K
2.2K
4.7K
R7094
D779
1.5K(E)
ERA9102
L732
PJDT101K
Fig.44
Fig.43
4.3V
0V
130V
0V
T1
T1
9µs
T2
T2
19µs
CLMON CN710-1
Lighting H
Lighting LO
RET (MAIN PWB)
CN707-2
CLCON
CN710-2
124V(SW)
CN710-4
CLPR
CN710-5