GREISINGER GMH3151 User Manual

GREISINGER GMH3151 User Manual

Handheld pressure-meter for gmsd or gmxd pressure sensors
Hide thumbs Also See for GMH3151:

Advertisement

Quick Links

H61.0.02.6C-04
for GMSD or GMXD - Pressure Sensors
CONTENTS
1
GENERAL ................................................................................................................................................ 2
1.1
1.2
1.3
1.4
.............................................................................................................................................. 3
1.5
2
CONFIGURATION.................................................................................................................................... 4
2.1
2.1.1
rAtE-Slo: Standard Measuring...................................................................................................... 5
2.1.2
rAtE-P.dEt: Peak detection .......................................................................................................... 5
2.1.3
rAtE-FASt: Fast filtered measuring .............................................................................................. 5
2.2
2.3
2.4
2.5
2.6
2.7
2.8
............................................................................................................................................... 6
2.8.1
Interface - Base Address ('Adr.') .................................................................................................. 6
2.8.2
Analogue Output - Scaling with DAC.0 and DAC.1 ..................................................................... 6
2.9
................................................................................................................................................. 6
3
OPERATION OF LOGGER ...................................................................................................................... 7
3.1
3.2
4
THE SERIAL INTERFACE ....................................................................................................................... 9
5
PRESSURE CONNECTION TO THE SENSORS ................................................................................... 10
6
ERROR AND SYSTEM MESSAGES...................................................................................................... 10
7
CALIBRATION SERVICES .................................................................................................................... 11
8
SPECIFICATION .................................................................................................................................... 11
9
DISPOSAL NOTES ................................................................................................................................ 11
GREISINGER
User's Manual
Handheld Pressure-Meter
GMH3151
....................................................................................................................... 2
..................................................................................................................................... 3
................................................................................................................................ 3
: „
......................................................................................................................... 5
('OFFS')................................................................................................ 6
('SCAL') ................................................................................................. 6
................................................................................................................................ 6
................................................................................................................................ 6
as of Version 6.4
................................................................................................ 2
[
] ................................................................................ 5
.................................................................................. 7
electronic GmbH
" ........................................................... 5
.............................................................. 5
.................................. 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMH3151 and is the answer not in the manual?

Questions and answers

Summary of Contents for GREISINGER GMH3151

  • Page 1: Table Of Contents

    H61.0.02.6C-04 User’s Manual Handheld Pressure-Meter GMH3151 as of Version 6.4 for GMSD or GMXD – Pressure Sensors CONTENTS GENERAL ..............................2 ........................2 AFETY EQUIREMENTS ....................2 PERATION AINTENANCE DVICE ............................. 3 ONNECTIONS .............................. 3 ISPLAY ..........................3 ASIC PERATION CONFIGURATION............................
  • Page 2: General

    H61.0.02.6C-04 User’s Manual GMH3151 page 2 of 12 1 General 1.1 Safety Requirements This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
  • Page 3: Connections

    H61.0.02.6C-04 User’s Manual GMH3151 page 3 of 12 1.3 Connections Output: Operation as interface: Connect to optically isolated interface adapter (accessory: GRS 3100, GRS3105 or USB3100) Operation as analogue output: Connection via suitable cable. Attention: The output mode has to be configured (p.r.t. 2.8) and...
  • Page 4: Configuration

    H61.0.02.6C-04 User’s Manual GMH3151 page 4 of 12 2 Configuration To change device settings, press Menu (key 4) for 2 seconds. This will activate the configuration menu (main display: „SEt“). Pressing key Menu changes between the menus, pressing 4(key 3) jumps to the referring parameters, which can be selected with key 4(key 3).
  • Page 5: Different Kinds Of Measuring: „Rate-Slo, -P.det, -Fast

    H61.0.02.6C-04 User’s Manual GMH3151 page 5 of 12 2.1 Different Kinds Of Measuring: „rAtE-Slo, -P.dEt, -FASt“ Three different kinds of measuring pressure are supported. Two of them (P.dEt and FASt) are working with high measuring frequency of more than 1000 measurings per second.
  • Page 6: Zero Displacement Sensor ('Offs')

    H61.0.02.6C-04 User’s Manual GMH3151 page 6 of 12 2.5 Zero Displacement Sensor ('OFFS') A zero displacement can be carried out for the measured value: value displayed = value measured - offset Standard setting: 'off' = 0.0°, i.e. no zero displacement will be carried out. Together with the scale correction (see below) this factor is mainly used to compensate for sensor deviations.
  • Page 7: Operation Of Logger

    H61.0.02.6C-04 User’s Manual GMH3151 page 7 of 12 3 Operation Of Logger The device supports two different logger functions: each time when „store“ (key 6) is pressed a measurement will be recorded. „Func-Stor“: measurements will automatically be recorded each interval, which was set in the logger „Func-CYCL“:...
  • Page 8: Func-Cycl": Automatic Recording With Selectable Logger-Cycle-Time

    H61.0.02.6C-04 User’s Manual GMH3151 page 8 of 12 3.2 „Func-CYCL“: Automatic Recording With Selectable Logger-Cycle-Time The Logger-Cycle-Time is settable (p.r.t. Configuration). For example „CYCL“ = 60: A measuring is recorded after each 60 seconds. When the slow measurement "rAtE-Slo" is chosen, additionally a low power function is available: „Lo.Po“.
  • Page 9: The Serial Interface

    H61.0.02.6C-04 User’s Manual GMH3151 page 9 of 12 4 The Serial Interface By means of the serial interface and a suitable electrically isolated interface adapter (GRS3100, GRS3105 or USB3100) the device can be connected to a computer for data transfer. With the GRS3105 up to 5 devices of the GMH3xxx- series can be connected to one interface (see also manual of GRS3100, GRS3105 or USB3100).
  • Page 10: Pressure Connection To The Sensors

    H61.0.02.6C-04 User’s Manual GMH3151 page 10 of 12 5 Pressure Connection To The Sensors The device is designed to be connected to the sensors of the GMSD/GMXD...-series without a new calibration being necessary. Therefore a great variety of replaceable sensors of e.g. –1.999...2.500 mbar relative up to 0...400.0 bar absolute pressure can be connected to the device.
  • Page 11: Calibration Services

    H61.0.02.6C-04 User’s Manual GMH3151 page 11 of 12 7 Calibration Services Calibration certificates – DKD-certificates – other certificates: If device should be certificated for its accuracy, it is the best solution to return it with the referring sensors to the manufacturer.