SPECIFICATIONS
Transmi ers (cont.)
22 Hz ELECTROMAGNETIC TRANSMITTER USER GUIDE
CD42-T2
Pipeline Dia:
Pressure, max : 2,500 psi [172 bar]
Dimensions:
Ba eries:
Ba ery Life:
Material:
Range, open
air:
Opera ng
Temp Range:
CD42-T1A
Pipeline Dia:
Pressure, max : 2,500 psi [172 bar]
Dimensions:
Ba eries:
Ba ery Life:
Material:
Range, open
air:
Opera ng
Temp Range:
Page 42 of 52
30 – 60 in.
[762 – 1524 mm]
12.85 in. x 4.375 in.
[326 x 111 mm]
C-Cell (6) Alkaline
Standard pulse: 375 hrs
Skip-one pulse: 500 hrs
Nylon
92
[28 m]
– 40°F to 140°F
[– 40°C to 60°C]
8 – 28 in.
[203 – 711.2 mm]
10.19 in. x 2.0 in.
[258.8 x 50.8 mm]
AA-Cell (6) Alkaline
Standard pulse: 500 hrs
Skip-one pulse: 678 hrs
304 Stainless Steel
45
[13.7 m]
– 40°F to 140°F
[– 40°C to 60°C]

Hide quick links: