22 Hz ELECTROMAGNETIC TRANSMITTER USER GUIDE
PLACING INTO SERVICE CONT.

CHECKLIST

Before placing a transmi er into service, always ensure that:
• Ba eries are fresh and of proper size and type.
• Ba ery polarity is properly observed.
• Serviceable O-rings are installed. Bri le and/or deformed
O-rings may not properly seal, thus compromising case
integrity.
• Transmi er case, caps, and cap threads and or cap screws are
clean and free of dents, ruptures, or other damage which could
compromise the transmi er components.

TROUBLESHOOTING

Connec on and Communica on
CDI transmi ers, when supplied with fresh ba eries of the proper size
and type, should automa cally transmit an electromagne c signal
unless custom-programmed at the factory for Delay On behavior.
If your transmi er fails to establish communica on a er following all
ba ery installa on procedures, contact CDI at 1-800-580-4234 or 918-
258-6068 for product support.

REMOVING TRANSMITTER FROM SERVICE

Remove ba eries from transmi er and carousel before storage.
Always remove ba eries before placing the unit into storage.
Failure to do so may result in damage and may void warranty.