22 Hz ELECTROMAGNETIC TRANSMITTER USER GUIDE
Installing Ba eries (SWX)
Ba ery loading procedure is the same as with The T1A, T1AHP, and
T1AVHP carousels. The only diff erence is that the SWX carousel is affi xed
to the pressure switch
and not detachable.
Installing SWX to Transmi er
Inspect threads and O-ring before installing.
Ensure O-ring is serviceable. A bri le and/or deformed O-ring may not
properly seal. Lubricate O-ring with a light coa ng of petroleum jelly
if dry.
Ensure threads are clean and free of ruptures, dents, and other damage.
nsure threads are clean and free of ruptures, den
NOTE: The SWX merely ac vates a transmi er at a factory-
programmed pipeline pressure. Transmi er behavior (delay-ON
mes, custom pulse pa erns, constant-ON transmission, and other
features) remain unaff ected by SWX installa on.
GETTING STARTED CD42 T1A/T1AHP/T1AVHP
y diff erence is that the SWX carousel is affi xed
er
Page 27 of 52