JLG 1200SJP Operation And Safety Manual page 111

Boom lift models
Table of Contents

Advertisement

C: Wheel Drive Hub - Reggiana Riduttori (S/N 134389 to Pres-
ent)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o'clock position and Check
port at 3 o'clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
3121141
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
5. Hydraulic Return Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator
6. Hydraulic Charge Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.
– JLG Lift –
6-19