Panasonic CU-3E19RBU-5 Service Manual page 102

Outdoor unit
Hide thumbs Also See for CU-3E19RBU-5:
Table of Contents

Advertisement

17.1.1.3
Three Indoor Unit Operation
Cooling Characteristic
[Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT)
Operation condition: High fan speed
Piping Length: 7.5m (24.6 ft)
230V 60Hz
A) Indoor unit capacity: Cooling (3.2 + 2.5 + 2.0: CS-E12RKUAW + CS-E9RKUAW + CS-ME7RKUA),
service mode frequency = 49Hz
66.000
65.000
64.000
63.000
62.000
61.000
60.000
59.000
58.000
57.000
10
20
30
8.500
8.000
7.500
7.000
6.500
6.000
5.500
5.000
4.500
4.000
10
20
30
190.000
185.000
180.000
175.000
170.000
165.000
160.000
10
20
30
40
50
60
70
80
Outdoor Air Temperature (°F)
40
50
60
70
80
Outdoor Air Temperature (°F)
40
50
60
70
80
Outdoor Air Temperature (°F)
102
ME7RKUA
E9RKUAW
E12RKUAW
90
100
110
120
90
100
110
120
90
100
110
120

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-4e24rbu-5

Table of Contents