17.1.1.2
Two Indoor Unit Operation
Cooling Characteristic
[Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT)
Operation condition: High fan speed
Piping Length: 7.5m (24.6 ft)
230V 60Hz
A) Indoor unit capacity: Cooling (3.2 + 2.5: CS-E12RKUAW + CS-E9RKUAW), service mode frequency = 42Hz
62.000
61.000
60.000
59.000
58.000
57.000
56.000
55.000
54.000
53.000
10
20
30
7.500
7.000
6.500
6.000
5.500
5.000
4.500
4.000
3.500
3.000
10
20
30
165.000
160.000
155.000
150.000
145.000
140.000
135.000
130.000
10
20
30
40
50
60
70
80
Outdoor Air Temperature (°F)
40
50
60
70
80
Outdoor Air Temperature (°F)
40
50
60
70
80
Outdoor Air Temperature (°F)
100
E9RKUAW
E12RKUAW
90
100
110
120
90
100
110
120
90
100
110
120