  • Page 2: Table Of Contents

    Table of Contents Introduction ..............................3 1. Radio Modem MR400 ..........................4 Radio Part MR400 ............................5 Modem Part ............................5 3. MR 400 Connectors ............................6 Antenna ..............................6 Serial Interface ............................6 RS232, RS422 and RS485 Connectors..................6 Distinguishing Data Modules by Colour ..................
  • Page 3: Introduction

    This operator manual serves as the primary document for familiarising users with the parameters of the radio modem, its properties, modifications and with the parameters of interfaces. In order to master all the functions of the radio modem and the MORSE system you should refer to other documents. Figure 1. Radio modem MR400 (MR300, MR160)
  • Page 4: Radio Modem Mr400

    1. Radio Modem MR400 (MR300, MR160 MR 400, MR300 and MR160 are conceptually new radio modems designed for transmitting data in the VHF and UHF bands. The radio modem uses 4-state FSK modulation providing for a maximum signalling rate of 21.68 kbit/s. The radio modem is of modular design with one to four standard RS232 ports (an RS422 or RS485 port can be used in place of two of them) available to the user.
  • Page 5: Radio Part Mr400

    2. Description of Functions Radio Part MR400 The architecture of MR400 (MR300, MR160) radio modems resolves most of the requirements placed on a top quality user friendly radio modem with a very short switching time between receiving and transmitting. Frequency synthesis enables software selection of an arbitrary channel from the given frequency range. The operation of the radio part is controlled and diagnosed by the microcontroller.
  • Page 6: Mr 400 Connectors

    3. MR 400 Connectors Antenna The antenna connector is of the N type, female, impedance 50 Ohm. The antenna cable must be fitted with an appropriate mate. We recommend using the RG213 50 Ohm cable. The H1000 cable should be used when the length of the antenna feeder exceeds 25 m.
  • Page 7: Ethernet

    Ethernet Connector RJ-45 for Ethernet 10BaseT and 100BaseT corresponds to the EIA TIA T568B standard. Informative LED diodes indicate: Tx – output from CU Rx – input to CU 100 – if lit the 100BaseT LINK network is indicated – indicates correctly connected F.D. link – indicates full duplex operation. A “straight” cable is needed for connecting to the Ethernet network via the hub (repeater) or switch-hub (router).
  • Page 8: Information Led

    passed to this terminal about the method of supply; level TTL0 – 230 V AC supply, TTL1 – battery supply. If the radio modem is supplied in another manner the method of supply is deduced according to the voltage (the value from which the supply is considered as supply from a battery can be set in SW).
  • Page 9: Service Connector Connections

    Figure 3.2. View of radio modem — description of connectors, model with DSUB (Canon) connectors and with terminalsO...
  • Page 10: Table Of Technical Parameters

    Table 4.1. Table of technical parameters TYPE Frequency range MR400: 380 – 470 MHz 406 – 412 MHz, 421 – 512 MHz MR300: 290 – 380 MHz MR160: 136 – 180 MHz Channel spacing 25 kHz or 12.5 kHz Method of setting the working frequency Software in the range 3.2 MHz...
  • Page 11: Dimensional Diagram

    5. Dimensional Diagram Figure 5.1. Mechanical dimensions of MR400...
  • Page 12: Labelling Radio Modems

    6. Labelling Radio Modems Figure 6.1. Serial codes of products...
  • Page 13: Conditions For Mr400 Operation

    7. Conditions for MR400 Operation Radio modem installation and maintenence Radio modems MR400 (MR300, MR160) shall always be installed by personell who have been trained by RACOM or by an authorised representative of RACOM. Information contained in the documentation, including this manual, can not fully substitute the training required.
  • Page 14: Conditions Of Liability For Defects And Instructions For Safe Operation Of Equipment

    The radio modem can only be operated on frequencies stipulated by the body authorised by the radio operation administration in the respective country and cannot exceed the maximum permitted output power. RACOM is not responsible for products used in an unauthorised way.
  • Page 15: Declaration Of Conformity

    Declaration of Conformity RACOM s. r. o. hereby declares that its radio modem MR400 (MR300, MR160) product complies with the basic requirements and other respective measures of regulation 1999/5/EC. This equipment therefore bears the CE marking. The warning exclamation mark in the circle marks the radio modem as class 2 equipment denoting radio equipment with...
  • Page 16: Limitations Of Use

    Limitations of Use. The MR400 radio modem has been developed for the frequency range 380 – 512 MHz. Specific Specific subranges are approved to be used in each country or region. A radio modem user must keep in mind that this radio device cannot be operated without the permission of the respective local radio spectrum administrator who provides a specific frequency for use and issues the appropriate permission for this.
  • Page 17 (without the prior written consent of the owner of the rights) is strictly forbidden. RACOM retains the right to make changes to the technical specification or functions of this product or to terminate production of this product, or to terminate service support of this product without advance written notice to the customer.