RACOM PROFI MR400 Operating Manual

Narrowband modems
Hide thumbs Also See for PROFI MR400:
Table of Contents

Advertisement

Quick Links

Operating manual
Narrowband modems – PROFI
MR400, MR300, MR160
version 4.9
3/31/2014
RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic
Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu
.
.
www.racom.eu

Advertisement

Table of Contents
loading

Summary of Contents for RACOM PROFI MR400

  • Page 1 Narrowband modems – PROFI MR400, MR300, MR160 version 4.9 3/31/2014 RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic www.racom.eu Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu...
  • Page 3: Table Of Contents

    3.11. Service cable connector connections ..................17 3.12. View of radio modem — description of connectors, model with DSUB (Canon) connectors and with terminals, numbering of slots ....................18 © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 4 3.9. Table of service connector connections ..................16 3.10. Slot options ..........................18 4.1. Table of technical parameters MR400, MR300, MR160 ............19 4.2. Standards complied ........................20 4.3. Railway Safety Appliance Standards Regulations ..............20 Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 5: Introduction

    In next description is used the notation modem or router instead of radiomodem. Fig. 1: Radio modem MR400 with Cannon connectors, MR300 with Cannon connectors and MR160 with screw clamps © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 6: Radio Modem Mr400 (Mr300, Mr160, Mr160P)

    The radio modem is equipment which can only be operated in the Czech Republic on the basis of Permission to operate transmitting radio stations issued by the Department of Fre- quency Spectrum Management at the Czech Telecommunication Office. Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 7: Description Of Radiomodem Functions

    Radio modems MR400 (MR300, MR160) are special devices which require skilled assembly. All supplied equipment is assembled by RACOM at the user’s site. For subsequent maintenance RACOM specially trains the user’s skilled staff and as an additional aid provides them with Operating regulations for radio data networks and MORSE Firmware –...
  • Page 8 Important CAUTION! Danger of explosion upon replacing the incorrect type of battery. Follow the manufacturers instructions for handling used batteries. Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 9: Connectors

    3.2.1. RS232, RS422 and RS485 Connectors a) Table of data connector RS232 connections Tab. 3.1: Table of data connector RS232 connections RS232 Screw DSUB9F signal terminals Fig. 3.1: RS232 DSUB9 female © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 10: Data Cable Rs485 Connections

    Tab. 3.3: Table for distinguishing LEDs for RxD and TxD by colour Type of interface Colour (RxD / TxD) RS232 red / green RS232 opt. separated orange / green RS422/485 opt. separated orange / yellow Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 11: Ethernet

    The following table contains connector connections and colours of conductors. For the crossed cable the order of conductors on one side is the same as for the direct cable. © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 12: Analog And Digital Inputs And Outputs

    - analog outputs Connector A IN - analog inputs Connector D OUT - digital outputs Connector D IN - digital inputs Terminal UP this clamps pair is not used Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 13: Description Of Analog And Digital Inputs And Outputs

    +A in any MORSE system equipment transmitter A in (e.g. MD160, MX 160, MWxxx, MRxxx, MC100, MG100i, ...) Fig. 3.7: Examples of wiring analog inputs and outputs © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 14: Gps Module

    Pin No. 3 becomes the input for configuration data, if we connect pin No. 8 to GND. • The behaviour of time pulses at pin No. 6 (default) +6 V -6 V 100 ms 900 ms http://www.u-blox.com/products/modules.html Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 15: Supply Connector

    Terminals of this connector are labelled in the standard manner. Only DC voltage in the range from 10.8 to 15.6 V can be connected. Connecting higher voltage may damage the radio modem. https://www.racom.eu/eng/support/firmware/mr400/index.html © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 16: Information Led

    Fig. 3.10: Service connector ground keying of TX carrier waves for service purposes Important ATTENTION! The service mode is not suitable for normal operation Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 17: View Of Radio Modem

    The only difference in appearance between the controller and the radio modem is the type designation badge and the absence of an antenna connector - see the following image. © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 18: View Of Radio Modem - Description Of Connectors, Model With Dsub (Canon) Connectors And With Terminals, Numbering Of Slots

    5 ADIO (analog and digital inputs and outputs) slot 4 Ethernet 10/100 Mbps slot 3 2×RS232 slot 2 RS232 or galv.sep. RS232 or RS422/RS485 or GPS slot 1 Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 19: Table Of Technical Parameters

    Weight 1.3 kg; 1.5 kg type of construction P 1) Availability of specific types and frequencies check here , please. Presently these types are under mass production. http://www.racom.eu/eng/products/rfp.html http://www.racom.eu/eng/products/radio-modems-mr400.html#specifications © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 20: Standards Complied

    1st slot. Therefore they are not recom- mended for use, and in an environment specified according to this standard no warranty applies to their use. Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 21: Dimensional Diagram And Labeling Modems

    In this case 4x M4 screws are used for mounting purposes. There are no centre holes in the P version for attachment to a DIN rail. Labelling Radio Modems is described in next table: © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 22 DIN rail clips , SCC connectors with screw terminals, SCC1 - RS485, optically separated, SCC2 - RS232, SCC3 - RS232, Ethernet 1 2014 Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.
  • Page 23: Modem Installation

    6. Modem installation 6.1. General description of installation Racom routers are built into a robust metal case and are suitable for applications which place them in various environments from air-conditioned offices to heavy industry factories. To a certain extent the method of installation needs to be adapted to this.
  • Page 24: Power Supply

    The distance between the persons and antenna minimal 5 m comply with applicable standards for human exposure of general public to RF electromagnetic fields, namely with standard EN 50385: 2002. It is valid for all power levels and all antenna types which firm Racom provides.
  • Page 25: Example Of The Layout Of Equipment In A Switchboard

    Modem installation Fig. 6.2: Example of the layout of equipment in a switchboard © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 26: Conditions For Mr400 Operation

    7.1. Important Warning RACOM s. r. o. (hereinafter referred to as RACOM) is the exclusive owner of all rights to this operator manual. All rights reserved. Any duplication of this manual in any way, shape or form, or translation to any other language (without the prior written consent of the owner of the rights) is strictly forbidden.
  • Page 27: Product Conformity

    1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Dutch Hierbij verklaart Racom s. r. o. dat het toestel MR400 (MR300, MR160) in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart Racom s. r. o. dat deze MR400 (MR300, MR160) voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.
  • Page 28 1999/5/CE. Spanish Por medio de la presente Racom s. r. o. declara que el MR400 (MR300, MR160) cumple con los re- quisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE Portuguese Racom s.
  • Page 29: Mr400 Consistency Declaration

    Nove Mesto na Morave, 22 of August 2005 Jiri Hruska, Managing Director RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic www.racom.eu Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu Fig.
  • Page 30: Mr300 Consistency Declaration

    Nove Mesto na Morave, 22 of August 2006 Jiri Hruska, Managing Director RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic www.racom.eu Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu Fig.
  • Page 31: Mr160 Consistency Declaration

    Nove Mesto na Morave, 14 of July 2006 Jiri Hruska, Managing Director RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic www.racom.eu Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu Fig.
  • Page 32: Country Of Origin

    Nove Mesto na Morave, 1 of March 2014 Jiri Hruska, CEO RACOM s.r.o. • Mirova 1283 • 592 31 Nove Mesto na Morave • Czech Republic www.racom.eu Tel.: +420 565 659 511 • Fax: +420 565 659 512 • E-mail: racom@racom.eu Fig.
  • Page 33: Limitations Of Use

    Users of MR400 radio modems in North America must be aware that because the 406.0 – 406.1 MHz frequency range is reserved only for the government the use of radio modems on these frequencies is strictly forbidden without proper permission. © RACOM s.r.o. – Narrowband modems – PROFI MR400, MR300, MR160...
  • Page 34: Revision History

    Radiomodem MR070 supplemented Revision 4.7 20012-03-19 removed the T-port, patch temperature specifications table Revision 4.8 20014-01-21 removed the M-Bus, MR070 Revision 4.9 20014-03-27 Added section Section 7.4, “Country of Origin” Narrowband modems – PROFI MR400, MR300, MR160 – © RACOM s.r.o.

This manual is also suitable for:

Profi mr300Profi mr160

Table of Contents