Step
5
Disconnect the
connectors one by one
starting from your side.
6
Remove the control
PCB.
2. Removing the
reactor
1
Remove the screw.
2
Remove the 3 screws
and lift the reactor
upward to remove it.
Removal Procedure
Procedure
Connectors
For inverter PCB
Connectors
For SPM PCB
Connectors
For display PCB
Connector S10: For relay
PCB
Connectors H1/H2: For DB
(diode bridge), power wire
harnesses
AC2
(black)
(R6431)
(R6432)
(R6433)
(R6434)
Outdoor Unit
Points
S33
& S71:
S31
& S32:
S51
& S101:
AC1
(red) and
287