Printed Circuit Board Connector Wiring Diagram; Indoor Unit - Daikin B-Series Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for B-Series:
Table of Contents

Advertisement

Printed Circuit Board Connector Wiring Diagram

1. Printed Circuit Board Connector Wiring Diagram
1.1

Indoor Unit

Connectors
1)
2)
3)
4)
5) S26,
6) S27, S29,
7)
8)
9)
10)
Note:
Other designations
1)
2)
3)
4)
5)
6)
7)
8)
9)
Note:
Following parts are not on FT(Y)S 50 / 60B series:
38
S1
Connector for fan motor
S6
Connector for swing motor (horizontal blades)
S8
Connector for swing motor (vertical blades)
S21
Connector for
S37
Connector for buzzer PCB
S36
Connector for control PCB
S28
Connector for signal receiver PCB
S32
Connector for heat exchanger thermistor
S35
Connector for Intelligent Eye sensor PCB
S38
Connector for display PCB
V1
Varistor
JA
Address setting jumper
JB
Fan speed setting
JC
Power failure recovery function
Refer to page 197 for detail.
SW1
Forced operation ON / OFF switch
LED1
LED for operation (green)
LED2
LED for timer (yellow)
LED3
LED for Home Leave operation (red)
LED A
Service monitor LED
FU1
Fuse
(3.15A)
RTH1
Room temperature thermistor
Intelligent Eye sensor PCB
S8
S35
LED3
centralized control
(HA)
when compressor is OFF on thermostat
(green)
Printed Circuit Board Connector Wiring Diagram