Specifications
Indoor Units
Model
Outdoor Units
Capacity (Min.~Max.)
Moisture Removal
Running Current
Power Consumption (Min.~Max.)
Power Factor
COP
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Color
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current
Power Consumption
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Model
Refrigerant
Charge
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Running Current
Power Consumption
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Drawing No.
Note:
Outdoor ; 35°CDB/24°CWB
32
Cooling
kW
0.9~5.9
kcal/h
775~5,070
L/h
2.9
A
8.00
W
450~2,300
%
99.4
W/W
2.86
mm
mm
mm
Both Liquid and Gas Pipes
m
m
m
g/m
H
15.4 (545)
M
12.9 (456)
L
10.8 (383)
SL
9.6 (339)
W
Steps
5 Steps, Quiet and Auto
Right, Left, Horizontal and Downward
Removable / Washable / Mildew Proof
A
0.19
W
40
%
95.7
Microcomputer Control
mm
mm
kg
kg
dBA
44/40/35/32
Hermetically Sealed Swing Type
W
L
kg
H
42.8 (1,511)
L
40.7 (1,437)
W
A
7.81
W
1,710
%
99.5
A
mm
mm
kg
kg
dBA
47/44
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 7°CDB/6°CWB
FTXD50BVMT
RXD50BVMT
Heating
0.9~8.0
775~6,880
9.10
450~2,800
98.9
3.28
φ
6.4
φ
12.7
φ
18.0
30
20
10
20
FTXD50BVMT
White
16.1 (569)
13.7 (485)
11.5 (406)
10.2 (359)
Cross Flow Fan
43
0.19
40
95.7
290×1,050×238
337×1,147×366
12
17
42/38/33/30
RXD50BVMT
Ivory White
2YC32UXD
1,500
SE50P
0.65
R-22
1.25
40.7 (1,437)
40.7 (1,437)
Propeller
53
8.91
1,940
99.0
9.1
735×825×300
784×960×390
49
54
48/45
3D040808A
Heating
Piping Length
Indoor ; 21°CDB
7.5m
60Hz 220V
FTXD60BVMT
RXD60BVMT
Cooling
Heating
0.9~6.5
0.9~8.1
775~5,590
775~6,970
3.9
9.60
9.60
460~2,710
460~2,600
99.4
99.4
2.79
3.39
φ
6.4
φ
15.9
φ
18.0
Both Liquid and Gas Pipes
30
20
10
20
FTXD60BVMT
White
16.2 (572)
17.1 (605)
13.6 (480)
14.8 (521)
11.4 (402)
12.5 (443)
10.2 (358)
10.9 (385)
Cross Flow Fan
43
5 Steps, Quiet and Auto
Right, Left, Horizontal and Downward
Removable / Washable / Mildew Proof
0.21
0.21
45
45
97.4
97.4
Microcomputer Control
290×1,050×238
337×1,147×366
12
17
45/41/36/33
44/40/35/32
RXD60BVMT
Ivory White
Hermetically Sealed Swing Type
2YC32UXD
1,500
SE50P
0.65
R-22
1.60
46.3 (1,634)
44.2 (1,560)
42.9 (1,514)
44.2 (1,560)
Propeller
53
9.39
9.39
2,055
2,055
99.5
99.5
9.6
735×825×300
784×960×390
53
57
49/46
49/46
3D040809A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications
Si04-306E

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents