5.2.1
The maximum permitted speed during the lifting of the luffing jib is changed in such a
way that the torque-forming current I
Desired Isq up
function of the angle of the luffing jib.
The rise of the torque-forming current I
acceleration.
If the value
maximum permitted speed for the lifting of the luffing jib increase. If the value
sired Isq up
The effective value of the current is composed of the vector addition of Isq and Isd. If
the effective value of the current is to be equal to the rated current during the lifting in
stationary operation, the value in parameter 819 must be input some percent smaller
than the rated current.
No.
819 Desired Isq up
06/05
06/05

Torque-forming current Isq

819 in the field weakening area. The permitted maximum speed is a
10,0
permitted maximum speed
7,5
5,0
2,5
0,0
-2,5
00:06
00:12
00:18
Desired Isq up
819 is reduced, both are reduced accordingly.
Parameter
Description
corresponds to the figure set with parameter
sq
I
sq
I
sd
00:24
00:30
00:36
00:42
at the 6 s point in time is needed for the
sq
819 is increased, the absolute current value and the
Min.
0.01 ⋅ I
actual speed
00:48
00:54
01:00
Setting
Max.
Fact. sett.
o ⋅ I
0.8 ⋅ I
FIN
FIN
01:06
min:s
De-
FIN